ManufacturerSeriesPart StatusTypeSpecificationsRatings
Supplier Part Number
Manufacturer Part Number
PriceStock
Manufacturer
Description
Series
Part Status
Type
Specifications
Ratings
BISZ CAP 1P
BISZ CAP 1P
Leadtime
2 3 weeks
Fluke ElectronicsGROUND TESTER GEO EARTH1623ObsoleteEarth Ground TestersMeasures Resistance 0.001 ~ 20 kOhmCAT II 300V
7A4F VUJD V8
7A4F VUJD V8
1+170.725
Increments of 1
Leadtime
2 3 weeks
Phoenix ContactCURRENT PLIER MULTIMETERTESTFOX CC 1ActiveCurrent Clamp MeterMeasures Voltage, Current and ResistanceCAT III 600V
GT I2 KO3
GT I2 KO3
1+196.029
Increments of 1
Leadtime
2 3 weeks
AmprobeDMM AC DC CLAMP ONACDCActiveCurrent Clamp MeterDMM Functions Include Voltage, Resistance and Current to 400ACAT III 600V
LDY UXFR 1BT
LDY UXFR 1BT
1+479.412
Increments of 1
Leadtime
2 3 weeks
AmprobeADVANCED WIRE TRACERATActiveWire TracerIdentifies Breakers, Open Circuits and Pinouts in Various Cable Types
8S0 4J H88
8S0 4J H88
1+303.912
Increments of 1
Leadtime
2 3 weeks
Fluke ElectronicsCURRENT CLAMP PROBE AC ActiveCurrent Clamp, Probe Add On Measures AC Current to 800A, Banana InterfaceCAT III 600V
ZU QE OQD
ZU QE OQD
1+220.539
Increments of 1
Leadtime
2 3 weeks
Amprobe600A POWER QUALITY CLAMPACDActiveCurrent Clamp MeterDMM Functions Include Voltage, Resistance, Frequency and Current to 600ACAT III 600V
MF20 OM7 BKN
MF20 OM7 BKN
1+588.225
Increments of 1
Leadtime
2 3 weeks
Fluke ElectronicsFLUKE 173X IFLEXI 6000A 36 3PKFluke Connect™ActiveCurrent Clamp, Probe Add On Measures AC Current to 6000A, BNC Interface
MQ W3O ZJD
MQ W3O ZJD
Leadtime
2 3 weeks
Greenlee CommunicationsCLAMPMETER AC DCCMObsoleteCurrent Clamp MeterDMM Functions Include Voltage, Resistance, Frequency and Current to 600ACAT III 600V
NQB TD 1R
NQB TD 1R
1+955.833
Increments of 1
Leadtime
2 3 weeks
AmprobeADVANCED WIRE TRACER, W HARD CASATActiveWire TracerIdentifies Breakers, Open Circuits and Pinouts in Various Cable Types
NFU-Q39-SN
NFU-Q39-SN
1+1666.62
Increments of 1
Leadtime
2-3 weeks
AmprobeGRND RESISTNCE TESTR CLAMP-ON-ActiveEarth Ground TestersMeasures Resistance 0.025 ~ 1.5 kOhmCAT III 600V
UX23 8F T0I
UX23 8F T0I
Leadtime
2 3 weeks
Greenlee CommunicationsADAPTER CURRENT FLEX ObsoleteCurrent Clamp, Probe Add On Measures AC Current to 3000A, Banana InterfaceCAT III 1000V
LW8 E27 F21
LW8 E27 F21
1+117.598
Increments of 1
Leadtime
2 3 weeks
Amprobe400A SWIVEL CLAMPACDActiveCurrent Clamp MeterDMM Functions Include Voltage, Resistance, Capacitance and Current to 400ACAT III 600V
9H 6G9O N9
9H 6G9O N9
1+784.304
Increments of 1
Leadtime
2 3 weeks
Fluke ElectronicsCLAMP METER TRUE RM AC DC 2000A350ActiveCurrent Clamp MeterDMM Functions Include Frequency and Current to 2000ACAT IV 600V
UHQW3 UY9Y Q0
UHQW3 UY9Y Q0
1+34.2647
Increments of 1
Leadtime
2 3 weeks
AmprobeBREAKER FINDER ActiveWire TracerIdentifies Breaker Location for 90 ~ 120V SystemsCAT II 120V
JLC RZ FZ
JLC RZ FZ
Leadtime
2 3 weeks
Fluke Electronics5000A FLUKE 1750 THIN FLEXI 122C ObsoleteCurrent Clamp, Probe Add On Measures AC Current to 5000A, BNC InterfaceCAT III 1000V, CAT IV 600V
WY TC 6T
WY TC 6T
1+166.618
Increments of 1
Leadtime
2 3 weeks
AmprobeDISPLAY DIG CLAMP ON DMM RMSACDActiveCurrent Clamp MeterDMM Functions Include Voltage, Resistance, Capacitance, Temperature, Frequency and Current to 600ACAT III 600V
J28 8A6H ZW
J28 8A6H ZW
1+196.069
Increments of 1
Leadtime
2 3 weeks
Fluke ElectronicsFC WIRELESS DC VOLT MODFluke Connect™ActiveVoltage DetectorMeasures DC Voltage 0.6 ~ 1000VDCCAT III 1000V, CAT IV 600V
RDPG PCOI 10
RDPG PCOI 10
1+176.422
Increments of 1
Leadtime
2 3 weeks
AmprobeDIGITAL CLAMP ON METER TRMSACDCActiveCurrent Clamp MeterDMM Functions Include Voltage, Resistance, Capacitance and Current to 1000ACAT III 600V
B7UZH 7MPC PO9
B7UZH 7MPC PO9
Leadtime
2 3 weeks
Greenlee CommunicationsINDICATOR MOTOR ROTATION ObsoletePhase Rotation IndicatorDetects the Rotary Field of Three Phase Systems
Q7IAF A0W OB
Q7IAF A0W OB
Leadtime
2 3 weeks
Greenlee CommunicationsCLAMPMETER ACCMObsoleteCurrent Clamp MeterDMM Functions Include Voltage, Resistance, Frequency and Current to 1000ACAT III 1000V, CAT IV 600V
AH HY8J 80
AH HY8J 80
1+24.0686
Increments of 1
Leadtime
2 3 weeks
Klein Tools, Inc.200A HOOK METER*Active
F7T23 U9 7MX
F7T23 U9 7MX
1+196.069
Increments of 1
Leadtime
2 3 weeks
Fluke ElectronicsFC WIRELESS DC VOLT MODFluke Connect™ActiveVoltage DetectorMeasures DC Voltage 0.6 ~ 1000VDCCAT III 1000V, CAT IV 600V
PEXLS WB4 KK
PEXLS WB4 KK
Leadtime
2 3 weeks
Fluke ElectronicsCLAMP METER 600AC TRUE RMS330ObsoleteCurrent Clamp MeterDMM Functions Include Voltage, Resistance and Current to 600ACAT III 600V
H5 OT J96
H5 OT J96
1+269.069
Increments of 1
Leadtime
2 3 weeks
Greenlee CommunicationsTESTER ELECTRICAL 1000V 600A ActiveCurrent Clamp MeterDMM Functions Include Voltage, Resistance and Current to 400ACAT III 1000V, CAT IV 600V
IUR TQE K4
IUR TQE K4
1+784.304
Increments of 1
Leadtime
2 3 weeks
Fluke ElectronicsEP2085A VOLTAGE PROBE 1000 V ActiveVoltage DetectorMeasures AC Voltage to 10 ~ 1700VACCAT IV 600V