Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Element Type | Temperature Range | Length - Lead Wire | Conductor Type | Terminal Type | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E52-IC10AE-N 2M![]() | E52-IC10AE-N 2M |
| Leadtime 2-3 weeks | LA1LG-ETRT-7ZH | T-COUPLE TYPE J L=100MM | E52 | Active | J - Type | 0 ~ 200°C | 2m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
V29-JMX-CG![]() | V29-JMX-CG |
| Leadtime 2-3 weeks | AC-FY-7T | T-COUPLE K L=15CM 4M HEAT RES | E52 | Active | K - Type | 0 ~ 900°C | 4m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
RE-EZ-X5J![]() | RE-EZ-X5J |
| Leadtime 2-3 weeks | F6-AWS-P1M | RTD L=100CM THERMO WELL | E52 | Active | Pt100 | -200°C ~ 450°C | - | 3 Conductor System | Enclosed Terminals | ||||||||||||||
RYF0K-4G-VC![]() | RYF0K-4G-VC |
| Leadtime 2-3 weeks | VIEG1-7R-CZF | TEMP PROBE | LTP | Active | Thermistor | -40 ~ 150°C | - | Non-Grounded | Connector | ||||||||||||||
E52-P15A D 3.2 8M![]() | E52-P15A D 3.2 8M |
| Leadtime 2-3 weeks | NC-Q2-LD | RTD TEMPERATURE SENSOR | E52 | Active | Pt100 | -200°C ~ 450°C | 8m | 3 Conductor System | Exposed Lead Wires | ||||||||||||||
55KT-4U-K9![]() | 55KT-4U-K9 |
| Leadtime 2-3 weeks | S69M-FQKV-7OT | TEMP PROBE | LTP | Active | Thermistor | -40 ~ 150°C | - | Non-Grounded | Connector | ||||||||||||||
B0RZV-HR-M1![]() | B0RZV-HR-M1 |
| Leadtime 2-3 weeks | UVCL-6N-HLQ | T-COUPLE TYPE J L=50CM 4M | E52 | Active | J - Type | 0 ~ 350°C | 8m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
E52-CA1D M6 2M![]() | E52-CA1D M6 2M | Leadtime 2-3 weeks | I85WF-LT31-J33 | THERMOCOUPLE | E52 | Obsolete | K - Type | 0 ~ 400°C | 2m | Grounded | Exposed Lead Wires | |||||||||||||||
E52-CA100B D=10![]() | E52-CA100B D=10 | Leadtime 2-3 weeks | T2C-X59-FH | THERMOCOUPLE | E52 | Obsolete | K - Type | 0 ~ 400°C | 1m | Non-Grounded | Exposed Lead Wires | |||||||||||||||
P4T4Y-0254-XF![]() | P4T4Y-0254-XF |
| Leadtime 2-3 weeks | E3F7-246-SNR | T-COUPLE K L=15CM 8M | E52 | Active | K - Type | 0 ~ 900°C | 8m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
4B-HKAV-4OE![]() | 4B-HKAV-4OE |
| Leadtime 2-3 weeks | SW0B9-3QB-8U | RTD L=100CM THERMO WELL | E52 | Active | Pt100 | -200°C ~ 450°C | - | 3 Conductor System | Enclosed Terminals | ||||||||||||||
E52-CA15AY D=1 4M![]() | E52-CA15AY D=1 4M |
| Leadtime 2-3 weeks | DMXPP-HZL6-YJ | T-COUPLE K L=15CM 4M | E52 | Active | K - Type | 0 ~ 900°C | 4m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
3LRY-MXN-Y8G![]() | 3LRY-MXN-Y8G | Leadtime 2-3 weeks | DRH-AHJB-8Q | TEMPATURE SENSOR | E52 | Obsolete | K - Type | 0 ~ 1050°C | - | Non-Grounded | Enclosed Terminals | |||||||||||||||
J8Z-0JS1-KNR![]() | J8Z-0JS1-KNR |
| Leadtime 2-3 weeks | S0VNB-DLT-CJ | T-COUPLE J L=150MM 4M SPRING | E52 | Active | J - Type | 0 ~ 350°C | 4m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
X54V-C58M-Q8![]() | X54V-C58M-Q8 |
| 1 | 1U1O-EL6V-B4 | RTD L=35CM THERMO WELL | E52 | Active | Pt100 | -200°C ~ 450°C | - | 3 Conductor System | Enclosed Terminals | ||||||||||||||
E52-IC10ASY 2M![]() | E52-IC10ASY 2M |
| 3 | 3HQAG-RPZ1-6B | T-COUPLE J L=100MM 2M SPRING | E52 | Active | J - Type | 0 ~ 350°C | 2m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
Q9CZ-MZ-CF0![]() | Q9CZ-MZ-CF0 |
| Leadtime 2 3 weeks | EWHGJ-8M-64 | THERMISTOR SENSOR | E52 | Active | Thermistor | 100°C ~ 200°C | 1m | Non Grounded | Exposed Lead Wires | ||||||||||||||
X536H-UASQ-NJR![]() | X536H-UASQ-NJR |
| 19 | 019-6BB-IHO | T-COUPLE J L=35CM THERMO WELL | E52 | Active | J - Type | 0 ~ 1050°C | - | Non-Grounded | Enclosed Terminals | ||||||||||||||
5N4F2-FJ7A-52![]() | 5N4F2-FJ7A-52 |
| Leadtime 2-3 weeks | NQ4B-GDWE-9Y9 | PROBE THERMOCOUPLE J-TYPE 400C | - | Active | J - Type | 0 ~ 400°C | 2m | Non-Grounded | Exposed Lead Wires | ||||||||||||||
7LH1C-92-MVN![]() | 7LH1C-92-MVN |
| Leadtime 2 3 weeks | S063S-86TA-9O3 | THERMISTOR SENSOR | E52 | Active | Thermistor | 100°C ~ 200°C | 1m | Non Grounded | Exposed Lead Wires | ||||||||||||||
240-080 | 240-080 |
| Leadtime 2-3 weeks | D2-XHCK-9B | THERMOCOUPLE WIRE K-TYPE 1M | - | Active | K - Type | -73°C ~ 482°C | 1m | - | Wire Terminal | ||||||||||||||
FO1V 2JI6 V2![]() | FO1V 2JI6 V2 |
| 5 | 5C54-ED6E-OGN | T COUPLE TYPE J L=15CM 4M | E52 | Active | J Type | 0 ~ 350°C | 4m | Non Grounded | Exposed Lead Wires | ||||||||||||||
PF-221Y-VQ![]() | PF-221Y-VQ |
| Leadtime 2-3 weeks | DNV-QEKY-AJ | RTD L=100CM THERMO WELL | E52 | Active | Pt100 | -200°C ~ 450°C | - | 3 Conductor System | Enclosed Terminals | ||||||||||||||
79696037![]() | 79696037 |
| Leadtime 2-3 weeks | D1M-2OJ-DQJ | PROBE PT100 CLASS B 200C ALUMN | - | Active | Pt100 | 0 ~ 200°C | 2m | 3 Conductor System | Exposed Lead Wires | ||||||||||||||
AD-19KG-PYD![]() | AD-19KG-PYD |