Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LPIS-12C-AZI | LPIS-12C-AZI |
| Leadtime 2-3 weeks | Y782E-97CC-D6 | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA | ||||||||||||||
TU-CF-UQ![]() | TU-CF-UQ | 78 | 78TQB-J17C-2E | 16MM, 0-5% VOLUME CO2 INFRARED G | - | Active | CO2 | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
Z2AI-3CZ0-U8![]() | Z2AI-3CZ0-U8 | Leadtime 2 3 weeks | G48M8-H4Z2-8H3 | 19MM, HYDROCARBON INFRARED GAS S | Active | Hydrocarbons | Voltage | 20°C ~ 55°C | 3 V ~ 5 V | 35mA | ||||||||||||||||||
27930![]() | 27930 | 3 | 3S-AT5U-NX | METHANE GAS SENSOR MODULE | - | Obsolete | Methane | - | - | 0 V ~ 5 V | -10°C ~ 50°C | 5V | 165mA | |||||||||||||||
OMWC5-IAF8-TWO![]() | OMWC5-IAF8-TWO |
| 8 | 8JP8F-OO-XK | SENSOR OZONE ANALOG VOLTAGE MOD | Active | Ozone | ±2% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||||
9VBT ZC5 6Z![]() | 9VBT ZC5 6Z |
| Leadtime 2 3 weeks | J4-S6F7-KV | SENSOR AIR QUAL ANALOG VLTG MOD | Active | Air Quality | ±2% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||||
0EI U3O GGJ | 0EI U3O GGJ |
| Leadtime 2 3 weeks | VY5-K9-FJ | CARBON MONOXIDE GAS SENSOR | Active | Carbon Monoxide | 0 V ~ 5 V | 20°C ~ 50°C | 5V | 160mA | |||||||||||||||||
KJ88-PSX-FE1![]() | KJ88-PSX-FE1 |
| Leadtime 2 3 weeks | SNOT-WJ-9W | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 4mA ~ 20mA | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
BSIP-AOE1-XX![]() | BSIP-AOE1-XX | 84 | 84J-03Q-Y5 | PR PELLISTOR PAIR 2V 175MA OC SO | VQ20 | Active | Hydrocarbons | - | - | Voltage | - | 2V | 175mA | |||||||||||||||
CCS801B-COPD-2![]() | CCS801B-COPD |
| Leadtime 2-3 weeks | GCDR-2VB-4TU | GAS SENSOR | - | Active | Air Quality | - | - | Voltage | -5°C ~ 50°C | 1.4V | - | ||||||||||||||
SQ-4JX-1R![]() | SQ-4JX-1R |
| 4 | 04WE-TI-1D9 | SENSOR NITR DIOX ANALOG VLTG MOD | - | Active | Nitrogen Dioxide | - | ±2% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
5Z0D-FU2-DZ![]() | 5Z0D-FU2-DZ | Leadtime 2-3 weeks | H9-E9-07 | IR SENSOR HEAD FOR 0-100% LEL AC | - | Active | Acetylene | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
DY3L-KJM-5HL![]() | DY3L-KJM-5HL |
| 9 | 9P45N-AO-OL | DGS ETOH DIGITAL GAS SENSOR MODU | Active | Alcohol | ±15% | USB | 20°C ~ 40°C | 2.6 V ~ 3.6 V | 4mA | ||||||||||||||||
T6713 | T6713 |
| Leadtime 2-3 weeks | XC-8X-O7 | CO2 MODULE 2000PPM DIFFUSION | Telaire® | Active | CO2 | - | ±2% | I²C | 14 ~ 140°F -10 ~ 60°C | 4.5 V ~ 5.5 V | 200mA | ||||||||||||||
1QAY-SW2-VBD![]() | 1QAY-SW2-VBD | Leadtime 2 3 weeks | DW5TN-W1-VXB | IR SENSOR HEAD FOR 0 5% 100% BRO | Active | Hydrocarbons | Voltage | 20°C ~ 60°C | 5V | 60mA | ||||||||||||||||||
8RD-O9-UW![]() | 8RD-O9-UW |
| Leadtime 2 3 weeks | G9QKI-VX-72 | SENSOR HYD SULF ANALOG VLTG MOD | Active | Hydrogen Sulfide | ±2% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||||
RDF1-YLV-PBS![]() | RDF1-YLV-PBS | 3 | 3DYZW-612-0K | SERIES 2, 19MM, 0 5% CO2 IR SENS | Active | CO2 | ±0.5% | Voltage | 20°C ~ 60°C | 3 V ~ 5 V | 60mA | |||||||||||||||||
5JNM-AW-S6![]() | 5JNM-AW-S6 |
| Leadtime 2-3 weeks | AEZB-K8-BFQ | CO2 MODULE W HEADER FOR AAS-AQS- | - | Active | CO2 | - | ±3% | I²C, PWM | -10°C ~ 60°C | 4.5 V ~ 5.5 V | 25mA | ||||||||||||||
T6613-C | T6613-C |
| Leadtime 2-3 weeks | JE75O-9JV8-Q40 | CO2 MODULE 2000PPM W GAS PORTS | Telaire® | Active | CO2 | - | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||||
H280-REY0-6SC![]() | H280-REY0-6SC |
| 1 | 1OL-SR9U-NN3 | SENS GAS HYD SULF ANALG CUR MOD | - | Active | Hydrogen Sulfide | - | ±3% | Current | -30°C ~ 55°C | - | - | ||||||||||||||
T5007![]() | T5007 | Leadtime 2-3 weeks | T5V-Z5UW-S86 | CO2 TEMP SENSOR WALL MNT 0-10V | T5000 | Obsolete | CO2 | - | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC | - | |||||||||||||||
75H-89TA-0OC | 75H-89TA-0OC |
| 47 | 47C3S-SI0-B0L | CO2 MODULE 2000PPM W GAS PORTS | Telaire® | Active | CO2 | - | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||||
3YH V5Y XOK![]() | 3YH V5Y XOK | 3 | 3U0Y-GXBJ-SJ5 | SERIES 2, 19MM, 0 2%CO2 & 0 5% 1 | Active | CO2, Methane | Voltage | 20°C ~ 60°C | 3 V ~ 5 V | 60mA | ||||||||||||||||||
4XK JUD2 QNP![]() | 4XK JUD2 QNP |
| 4 | 4PPT-T1-YJJ | KGZ 12 HIGH ACCURACY OXYGEN | Active | Oxygen | 2 mbar ~ 3 bar | < 5 mbar | Voltage | 700°C | 4V | 40mA | |||||||||||||||
0V90 4L 943![]() | 0V90 4L 943 | 38 | 38ZE3-HZG3-2GY | CO2 TEMP SENSOR WALL MNT 0 10V | T5000 | Obsolete | CO2 | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC |