Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KJS-96-XC![]() | KJS-96-XC | 2 | 2VJ9-G9I-OF | IR SENSOR HEAD FOR 0-5% 100% BRO | - | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
IR604 1![]() | IR604 1 | Leadtime 2-3 weeks | D40D-ROWC-F3 | IR SENSOR HEAD FOR 0-100% LEL AC | - | Active | Acetylene | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
SL-RC5N-48![]() | SL-RC5N-48 | 1 | 1ZZFX-UI-W4 | PELLISTOR PR 3.5V 90MA TC C CAN | VQ30 | Active | Hydrocarbons | - | - | Voltage | - | 2 V ~ 3.45 V | 100mA | |||||||||||||||
1T8R RTY5 1Y![]() | 1T8R RTY5 1Y |
| 6 | 6KL-QCL-W7N | CO2 MODULE 50000PPM FLOW THROUGH | Active | CO2 | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | |||||||||||||||||
CH-AZ8C-HPU![]() | CH-AZ8C-HPU |
| Leadtime 2-3 weeks | LS2-PH1-1NI | SENS GAS AIR QUAL ANALG CUR MOD | - | Active | Air Quality | - | - | Current | -10°C ~ 40°C | - | - | ||||||||||||||
0Q S0 4GH![]() | 0Q S0 4GH |
| Leadtime 2 3 weeks | KK-1UC3-X8 | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 4mA ~ 20mA | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
2A-85JX-V57![]() | 2A-85JX-V57 | Leadtime 2-3 weeks | NZAH-AD-R3 | VQ31 PELLISTOR VQ600 HEAD, METRI | VQ600 | Active | Light Gases | - | - | Voltage | -20°C ~ 60°C | 3.5V | 90mA | |||||||||||||||
YW4K-BK1-T0![]() | YW4K-BK1-T0 |
| Leadtime 2-3 weeks | K6ZN-N1X-ET | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
T8031-5V![]() | T8031-5V |
| Leadtime 2-3 weeks | GP-THRF-I3 | CO2 TRANSMITTER INDUCT MOUNT 0-5 | Ventostat® | Active | CO2 | - | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA | ||||||||||||||
110-401![]() | 110-401 |
| Leadtime 2-3 weeks | W49-RU-1W | SENSOR GAS OZONE ANALOG CUR MOD | - | Active | Ozone | - | ±3% | Current | -30°C ~ 50°C | - | - | ||||||||||||||
MF020-0-LC3![]() | MF020-0-LC3 |
| 34 | 34E-FN-CS | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 4mA ~ 20mA | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
8DUY5-3T-2J | 8DUY5-3T-2J |
| 1 | 1G-TCSV-SQM | CARBON MONOXIDE GAS SENSOR | Active | Carbon Monoxide | 0 V ~ 5 V | 20°C ~ 50°C | 5V | 160mA | |||||||||||||||||
X7ZAH-XW-SSG![]() | X7ZAH-XW-SSG |
| Leadtime 2-3 weeks | W53-BU0-LX9 | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
SEN-09405![]() | SEN-09405 |
| Leadtime 2-3 weeks | ZVZ-CG4-C0 | LPG GAS SENSOR - MQ-6 | * | Active | - | - | - | - | - | - | - | ||||||||||||||
27932![]() | 27932 | Leadtime 2-3 weeks | BROL-48R-VZ2 | PROPANE GAS SENSOR MODULE | - | Obsolete | Propane | - | - | 0 V ~ 5 V | 0°C ~ 70°C | 5V | 175mA | |||||||||||||||
OT-4QT0-W2![]() | OT-4QT0-W2 |
| Leadtime 2-3 weeks | HGKN-60KV-N8S | SENSOR GAS CO2 ANALOG VLTG MOD | - | Active | Carbon Monoxide | - | ±3% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
OX7AT N6 3NE![]() | OX7AT N6 3NE | Leadtime 2 3 weeks | 0PFMA-N80E-TP | PR PELLISTOR PAIR 2V 175MA OC SO | VQ20 | Active | Hydrocarbons | Voltage | 2V | 175mA | ||||||||||||||||||
XC-601P-XI![]() | XC-601P-XI |
| Leadtime 2-3 weeks | LLP-I3BZ-5Y | SENSOR NITR DIOX ANALOG VLTG MOD | - | Active | Nitrogen Dioxide | - | ±2% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
AO7-AFY4-HL![]() | AO7-AFY4-HL |
| 1 | 1XK-TJBI-R17 | GAS SENSOR | - | Active | Air Quality | - | - | Voltage | -5°C ~ 50°C | 1.4V | - | ||||||||||||||
MF020-2-LC3![]() | MF020-2-LC3 |
| Leadtime 2-3 weeks | MGY-ZY5Q-DK | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 4mA ~ 20mA | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
4XK JUD2 QNP![]() | 4XK JUD2 QNP |
| Leadtime 2 3 weeks | GI-NKF-5X | KGZ 12 HIGH ACCURACY OXYGEN | Active | Oxygen | 2 mbar ~ 3 bar | < 5 mbar | Voltage | 700°C | 4V | 40mA | |||||||||||||||
VQ548ZD-S![]() | VQ548ZD-S | Leadtime 2-3 weeks | 0UT-CAP-ZKP | 3.0V - VQ548ZD - ZERO TESTED | VQ500 | Active | Hydrocarbons | - | - | Voltage | -40°C ~ 55°C | 3 V ~ 4.2 V | 60mA | |||||||||||||||
GAL-0B-5J | GAL-0B-5J |
| Leadtime 2 3 weeks | MJH4I-K7I-BR | CO2 MODULE 2000PPM DIFFUSION | Telaire® | Active | CO2 | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | ||||||||||||||||
04 5YY2 SW![]() | 04 5YY2 SW | Leadtime 2 3 weeks | H3J-UT6V-D82 | 19MM, 0 5% VOLUME CO2 INFRARED G | Active | Hydro Generator | Voltage | 20°C ~ 55°C | 3 V ~ 5 V | 35mA | ||||||||||||||||||
2S-HK-Y3 | 2S-HK-Y3 |
| Leadtime 2-3 weeks | OYF-9H-3BD | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA |