Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Relay Type | Function | Circuit | Delay Time | Output Type | Contact Rating @ ... | Voltage - Supply | Mounting Type | Termination Style | Timing Adjustment ... | Timing Initiate Method ... | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8-1423164-6![]() | 8-1423164-6 |
| 5 | 5I-TQRT-K3 | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
H5CN-XAN DC12-48![]() | H5CN-XAN DC12-48 |
| Leadtime 2-3 weeks | Z4T4-BZ-6MD | TIMER DGTL 4DIGIT DISPLAY 8PIN | H5CN | Active | Integrated | On-Delay | SPDT 1 Form C | 0.001 Sec ~ 9.999 Sec | Mechanical Relay | 3A @ 250VAC | 12 ~ 48VDC | Socket | 8 Pin Socketable | Up Down Digit Keys | Input Voltage | ||||||||||
LI5GS-P0S-KN![]() | LI5GS-P0S-KN |
| Leadtime 2-3 weeks | S9RI-6E-EJ | RELAY TIME DELAY INTERVAL 110VAC | QHS | Active | Integrated | Interval | - | Fixed, 12 Hrs | Solid State Relay | - | 110VAC | Chassis Mount | Quick Connect - 0.250 6.3mm | Fixed | Input Voltage | ||||||||||
88865215 | 88865215 | Leadtime 2-3 weeks | UMP3-5NP-VZ | RELAY TIME ANALOG 8A 24-240V DIN | TA2R1 | Obsolete | Integrated | On-Delay | DPDT 2 Form C | 0.1 Sec ~ 100 Hrs | Mechanical Relay | 8A @ 250VAC | 24 ~ 240VAC, 24VDC | DIN Rail | Screw Terminal | Hand Dial | Input Voltage, Trigger Signal | |||||||||||
2-1423152-3![]() | 2-1423152-3 |
| 59 | 059-J04-HW | COMMERCIAL 7000 | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
S1DXM-M2C60M-AC24V![]() | S1DXM-M2C60M-AC24V |
| 9 | 9A-W93-REV | ANALOG TIMER S1DXM MULTI-RANGE | S1DXM | Active | Integrated | Programmable Multi-Function | DPDT 2 Form C | 0.5 Sec ~ 60 Min | Mechanical Relay | 7A @ 250VAC | 24VAC | Socket | Socketable | Hand Dial | Input Voltage | ||||||||||
CG5 FV PV![]() | CG5 FV PV |
| 9 | 9SK-Q58-FL8 | SS TIMR ON DLY, 2S, 220VAC DC | * | Active | |||||||||||||||||||||
7022VCI2![]() | 7022VCI2 |
| Leadtime 2-3 weeks | KV-WB-1I | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
1-1423161-3![]() | 1-1423161-3 |
| Leadtime 2-3 weeks | ON4-OY-TIB | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
9-1472973-1![]() | 9-1472973-1 |
| Leadtime 2-3 weeks | A5-XJ-6BD | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
A7NA-O3-KDK![]() | A7NA-O3-KDK |
| 3 | 3K4-G6-72 | TIMER | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
7012PDX![]() | 7012PDX |
| Leadtime 2-3 weeks | I7D0R-2VB-JO | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
H3JA-8A 200-240VAC 10S![]() | H3JA-8A 200-240VAC 10S | 9 | 9W3TQ-343W-FQ9 | RELAY TIMER SPDT 1-10SEC 240VAC | H3JA | Obsolete | Integrated | On-Delay | SPDT 1 Form C | 1 Sec ~ 10 Sec | Mechanical Relay | 7A @ 250VAC | 200 ~ 240VAC | Socket | 8 Pin Socketable | Hand Dial | Input Voltage | |||||||||||
3RP1525-1AP30![]() | 3RP1525-1AP30 | 9 | 9R4P-OC-IW | RELAY TIME DELAY 3A 200-240 VAC | 3RP1 | Obsolete | Integrated | On-Delay | SPDT 1 Form C | 0.05 Sec ~ 100 Hrs | Mechanical Relay | 3A @ 250VAC | 200 ~ 240VAC | DIN Rail | Screw Terminal | Screwdriver Slot | Input Voltage, Trigger Signal | |||||||||||
SASP10S220AD![]() | SASP10S220AD |
| Leadtime 2-3 weeks | 0C7TJ-ULC-XMR | SS TIMR ON DLY, 10S ADJ, 220VAC | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
4-1423162-4![]() | 4-1423162-4 |
| Leadtime 2-3 weeks | LN3-JLP1-KU | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
1-1423160-0![]() | 1-1423160-0 |
| Leadtime 2-3 weeks | ZX-01N-ZHG | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
7012BD![]() | 7012BD |
| Leadtime 2-3 weeks | IVGPV-IOID-771 | RELAY TIME DELAY DPDT 240VAC | 7000, AGASTAT | Active | Integrated | On-Delay | DPDT 2 Form C | 5 Sec ~ 50 Sec | Mechanical Relay | 10A @ 240VAC | 240VAC | Panel Mount | Screw Terminal | Hand Dial | Input Voltage | ||||||||||
2-1423160-9![]() | 2-1423160-9 |
| 3 | 3BC-TTD5-P9 | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
CDB-38-70002![]() | CDB-38-70002 |
| Leadtime 2-3 weeks | STP-VNSG-TWB | RELAY TIME DELAY DPDT 120 VAC 8 | CD | Active | Integrated | On-Delay | DPDT 2 Form C | 0.1 Sec ~ 5 Sec | Mechanical Relay | 10A @ 277VAC | 120VAC | Socket | 8 Pin Socketable | Hand Dial | Input Voltage | ||||||||||
CUH-41-30010![]() | CUH-41-30010 |
| Leadtime 2-3 weeks | DAD-5PT-K8Z | RELAY TIME DELAY DPDT 10A 24VDC | CU | Active | Integrated | On-Delay | DPDT 2 Form C | 1 Sec ~ 10 Sec | Mechanical Relay | 10A @ 277VAC | 24VDC | Socket | Socketable | External Resistor | Input Voltage | ||||||||||
3L-MVGU-PY![]() | 3L-MVGU-PY |
| Leadtime 2-3 weeks | XK81G-H6Z-XI | SS TIMR RPT CYCLE, 1S, 220VAC | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||||||
QAS4M220ADL![]() | QAS4M220ADL |
| Leadtime 2-3 weeks | UCGHU-DSL-C32 | RELAY TIME ON-DELAY 220VAC QC | QAS | Active | Integrated | On-Delay | - | Fixed, 4 Min | Solid State Relay | - | 220VAC | Chassis Mount | Quick Connect - 0.250 6.3mm | Fixed | Input Voltage | ||||||||||
H2C-8-AC240-A![]() | H2C-8-AC240-A |
| Leadtime 2-3 weeks | GOJ-RIE-SW | MOTOR TIMER 8PIN SOCKET 240V | H2C | Active | Integrated | Motor Timer | SPDT 1 Form C | 1.25 Sec ~ 30 Hrs | Mechanical Relay | 6A @ 250VAC | 240VAC | Socket | 8 Pin Socketable | Hand Dial | Input Voltage | ||||||||||
1-1437453-7![]() | 1-1437453-7 |
| Leadtime 2-3 weeks | HJ-8MU-94V | RELAY TIME DELAY | * | Active | - | - | - | - | - | - | - | - | - | - | - |