ManufacturerSeriesPart StatusTypeFunctionActuator TypeOperating PressureOrifice DiameterFluid TypeConnection MethodFor Use With/Related ProductsMounting TypeFeatures
Supplier Part Number
Manufacturer Part Number
PriceStock
Manufacturer
Description
Series
Part Status
Type
Function
Actuator Type
Operating Pressure
Orifice Diameter
Fluid Type
Connection Method
For Use With/Related ...
Mounting Type
Features
81548051
81548051
Leadtime
2-3 weeks
ER6-XVJO-2XSOLENOID VALVE 3 2 NO CHASSIS MT-ObsoleteSolenoid Valve3 2 Normally Open-15 ~ 116 PSI 1 ~ 8 bar 0.032 0.80mm Air, Inert Gas, LiquidThreaded M5-Chassis MountManual Override, Supply Voltage 24VDC
Z6-D9-23Y
Z6-D9-23Y
1+139.275
10+137.336
25+135.402
50+116.059
Increments of 1
Leadtime
2-3 weeks
0J0X-MLH2-EFLIMPULSE GENERATOR SUB-BASE MOUNT-ActiveImpulse Generator, Fixed--30 ~ 116 PSI 2 ~ 8 bar 0.106 2.70mm Air, Inert Gas--Sub-Base MountDelay Time 0.4sec
1XRM-PQ-ID
1XRM-PQ-ID
1+60.0882
Increments of 1
Leadtime
2-3 weeks
B7QU-GI9W-MW0SOLENOID VALVE 3 2 NC SUBBASE MT-ActiveSolenoid Valve3 2 Normally Closed-15 ~ 116 PSI 1 ~ 8 bar 0.032 0.80mm Air, Inert Gas--Sub-Base MountRotatable Connector, Supply Voltage 24VDC
JQJZ-IF6-F8X
JQJZ-IF6-F8X
1+60.0882
Increments of 1
Leadtime
2-3 weeks
BDNM-4XD-3Y7SOLENOID VALVE 3 2 NC SUBBASE MT-ActiveSolenoid Valve3 2 Normally Closed-15 ~ 116 PSI 1 ~ 8 bar 0.032 0.80mm Air, Inert Gas--Sub-Base MountRotatable Connector, Supply Voltage 24VDC
JZFK-0LC-QM
JZFK-0LC-QM
1+7.79412
Increments of 1
Leadtime
2 3 weeks
QOIG-DZB-CAPSOLENOID VALVE ONEWAY FREE HANG ActiveSolenoid ValveOne Way 2.9 ~ 116.03 PSI 0.2 ~ 8 bar LiquidThreaded 3 4 NPT Free Hanging In Line
3333-DM-3F
3333-DM-3F
1+45.3725
10+44.7402
25+44.1102
50+37.8088
100+36.5485
Increments of 1
Leadtime
2-3 weeks
ZT5-0MC-3IPNEUM VALVE END BASE PAIR DIN-Active----------
KA 2B XH
KA 2B XH
1+38.6078
10+38.0755
25+37.5392
50+32.1765
100+31.1039
Increments of 1
Leadtime
2 3 weeks
DYSB-NZ-2FLOGIC YES ELEMENT SUB BASE MOUNT ActiveLogic ElementLOGIC YES 30 ~ 116 PSI 2 ~ 8 bar 0.106 2.70mm Air, Inert Gas Sub Base MountPressure Indicator
81510001
81510001
1+544.892
Increments of 1
77KO-XP-VJWAMPLIFIER RELAY POS OUT SUB-BASE-ActiveAmplifier RelayPositive Output-7 ~ 36 PSI 0.5 ~ 2.5 bar -Air, Inert GasPush-In Connection for Tubing 5 32 4.00mm Dia-Sub-Base MountInput Pressure 0.5 ~ 1.5mb
OE-55-W8
OE-55-W8
Leadtime
2-3 weeks
N9DG2-DSLF-RQSOLENOID VALVE 3 2 NC CHASSIS MT-ObsoleteSolenoid Valve3 2 Normally Closed-0 ~ 30 PSI 0 ~ 2 bar 0.059 1.50mm Air, Inert Gas, LiquidThreaded M5-Chassis MountManual Override, Supply Voltage 24VDC
WKMBD-2P6-YYZ
WKMBD-2P6-YYZ
1+107.598
10+106.1
25+104.605
50+89.6618
100+86.673
Increments of 1
Leadtime
2-3 weeks
LY-6NU2-Y4CONTROL VALVE 3 2 NC PANEL MOUNT-ActiveControl Valve, Momentary3 2 Normally ClosedPaddle30 ~ 116 PSI 2 ~ 8 bar 0.106 2.70mm Air, Inert GasPush-In Connection for Tubing 5 32 4.00mm Dia-Panel MountOperating Force 8 ~ 18N
81580504
81580504
1+783.529
10+772.647
Increments of 1
Leadtime
2-3 weeks
JXRO2-7AYE-8ZCCONTROL RELAY 2-HAND START CHAS-ActiveControl Relay2-Hand StartPushbutton, Dual30 ~ 116 PSI 2 ~ 8 bar 0.098 2.50mm Air, Inert GasPush-In Connection for Tubing 5 32 4.00mm Dia-Chassis Mount-
CMV-8WUG-AQ0
CMV-8WUG-AQ0
5+39.7059
Increments of 5
Leadtime
2-3 weeks
P2VL-2M-6ISLOGIC OR ELEMENT FREE HANGING-ActiveLogic ElementLOGIC OR-30 ~ 116 PSI 2 ~ 8 bar 0.106 2.70mm Air, Inert GasPush-In Connection for Tubing 5 32 4.00mm Dia-Free Hanging In-Line -
U6 YMV 3J
U6 YMV 3J
1+22.8725
10+22.5529
25+22.2353
50+19.0588
100+18.4235
Increments of 1
99A8I-LJ-MLRSUB BASE CHASSIS MOUNT ActiveSub Base Push In Connection for Tubing 5 32 4.00mm DiaLogic ElementChassis Mount
XQSZ6 ZD 8M0
XQSZ6 ZD 8M0
1+69.9118
Increments of 1
44V3N-6Y-5WSOLENOID VALVE 3 2 NC SUBBASE MT ActiveSolenoid Valve3 2 Normally Closed 15 ~ 116 PSI 1 ~ 8 bar 0.020 0.50mm Air, Inert Gas Sub Base MountManual Override, Supply Voltage 12VDC
XX00-G1D7-FP
XX00-G1D7-FP
2+119.833
Increments of 2
Leadtime
2-3 weeks
XX-0B-372CONTROL VALVE 4 2 SUBBASE MNT-ActiveControl Valve, Momentary4 2-44 ~ 116 PSI 3 ~ 8 bar 0.118 3.00mm Air, Inert Gas--Sub-Base Mount-
X8-0RP-TD
X8-0RP-TD
10+80.902
Increments of 10
Leadtime
2-3 weeks
XD5DP-ZD-K2SOLENOID VALVE 3 2 NC SUBBASE MT-ActiveSolenoid Valve3 2 Normally Closed-30 ~ 116 PSI 2 ~ 8 bar 0.106 2.70mm Air, Inert Gas--Sub-Base MountManual Override, Rotatable Connector, Supply Voltage 24VAC
5L-17-E0T
5L-17-E0T
1+89.902
Increments of 1
Leadtime
2-3 weeks
SU7J-UFK6-B4SWITCH PRESSURE OPERATED DIN RL-ActivePressure SwitchPressure Operated-30 ~ 116 PSI 2 ~ 8 bar 0.098 2.50mm Air, Inert GasPush-In Connection for Tubing 5 32 4.00mm Dia-DIN Rail-
CQF1K-43-GE
CQF1K-43-GE
1+326.049
10+321.184
25+306.585
Increments of 1
Leadtime
2-3 weeks
LN-LO2C-3CEVACUUM SWITCH POS OUT SUBBASE MT-ActiveVacuum SwitchPositive Output--1 ~ -13 PSI -0.1 ~ -0.9 bar -Air, Inert Gas--Sub-Base Mount-
D25P TTD 0Y
D25P TTD 0Y
1+53.2941
10+52.5539
25+51.8137
50+44.4118
100+42.9314
Increments of 1
Leadtime
2 3 weeks
WNAN-YUM0-FCSOLENOID VALVE 3 2 NC SUBBASE MT ActiveSolenoid Valve3 2 Normally Closed 15 ~ 116 PSI 1 ~ 8 bar 0.020 0.50mm Air, Inert Gas Sub Base MountManual Override, Rotatable Connector, Supply Voltage 110VAC
4K-OR-AU
4K-OR-AU
1+58.0588
Increments of 1
11Z-NGF-Q3SUB-BASE END DIN RAIL-ActiveSub-Base, End--30 ~ 116 PSI 2 ~ 8 bar --Push-In Connection for Tubing 6.00mm DiaControl ValveDIN Rail-
MPFAG XJ6Z XR
MPFAG XJ6Z XR
1+33.951
10+33.4814
25+33.0098
Increments of 1
Leadtime
2 3 weeks
S3Y-BL-1BRVAC GEN PRES OPERATED FREE HANG ActiveVacuum GeneratorPressure Operated 30 ~ 116 PSI 2 ~ 8 bar Air, Inert GasPush In Connection for Tubing 5 32 4.00mm Dia Free Hanging In Line
81529006
81529006
1+29.9118
10+26.998
25+25.8667
50+24.25
100+23.4417
Increments of 1
Leadtime
2-3 weeks
M96-MR5-8UBFLOW RESTRICT ONE-WAY FREE HANG-ActiveFlow Restrictor, FixedOne-Way-15 ~ 116 PSI 1 ~ 8 bar 0.024 0.60mm Air, Inert GasPush-In Connection for Tubing 5 32 4.00mm Dia-Free Hanging In-Line -
LZFL-TP8-DD1
LZFL-TP8-DD1
1+141.706
Increments of 1
Leadtime
2-3 weeks
PQR7P-BM-XSTIMER FIXED ON-DELAY SUB-BASE MT-ActiveTimer, FixedOn-Delay-30 ~ 116 PSI 2 ~ 8 bar 0.106 2.70mm Air, Inert Gas--Sub-Base MountDelay Time 0.4sec
P17DH-BVP-4WE
P17DH-BVP-4WE
20+41.0863
Increments of 20
Leadtime
2-3 weeks
FQ-5XR-D9MLOGIC OR ELEMENT SUB-BASE MOUNT-ActiveLogic ElementLOGIC OR-30 ~ 116 PSI 2 ~ 8 bar 0.106 2.70mm Air, Inert Gas--Sub-Base MountPressure Indicator
OW8-JM-4RU
OW8-JM-4RU
Leadtime
2 3 weeks
L6-PFVX-LJSUB BASE ROD MOUNT ObsoleteSub Base Push In Connection for Tubing 5 32 4.00mm Dia, 5 16 8.00mm DiaControl ValveRod Mount