Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Trip Status | Trip Range | Delay Time | Voltage - Supply | Output Type | Circuit | Contact Rating @ ... | Mounting Type | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
10F-SM-JX![]() | 10F-SM-JX | Leadtime 2-3 weeks | J0-0UU6-XW | CONTROL RELAY PHASE 3X480VAC DIN | * | Obsolete | - | - | - | - | - | - | - | - | - | |||||||||||||
QWO6T-X6-VT![]() | QWO6T-X6-VT |
| Leadtime 2-3 weeks | ZZER-DHP-CTR | 17.5 MM ASY PHASE SEQUENCE LO | K8DS | Active | Voltage Asymmetry, Phase Loss, Phase Sequence | - | - | 0.1 Sec ~ 30 Sec | 380 ~ 480VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||
1LJ-4S-LK![]() | 1LJ-4S-LK | Leadtime 2 3 weeks | QL-5B-K6 | EWA2 230VAC | * | Obsolete | ||||||||||||||||||||||
MM7UY-LPTX-4T![]() | MM7UY-LPTX-4T |
| Leadtime 2-3 weeks | V5RV-IJQL-VA | RELAY AC CUR SENS 120VAC CHAS MT | CR4395 | Active | Current Sensing AC | Energized Low | 6.0 ~ 60A AC | 2 Sec ~ 25 Sec | 120VAC | Electromechanical Relay | SPDT 1 Form C | 20A @ 240VAC | Chassis Mount | ||||||||||||
01LM-U8WJ-FP![]() | 01LM-U8WJ-FP |
| 7 | 7GT4-UUS-ZP2 | CURNTTRANSNPN 2 500MA PSH IN | K8DT | Active | Current Sensing AC DC | 2 ~ 500mA AC DC | 0.1 Sec ~ 30 Sec | 24VAC DC | Solid State | NPN | DIN Rail | ||||||||||||||
73U-NCM-JY![]() | 73U-NCM-JY |
| Leadtime 2-3 weeks | N13J-P1-A7D | UNDROVRVOLT TRNS 1 -150V PSHIN | K8DT | Active | Voltage Sensing AC DC | - | 1 ~ 150V AC DC | 0.1 Sec ~ 30 Sec | 100 ~ 240VAC | Solid State | NPN | - | DIN Rail | ||||||||||||
G7E-S2W-SDI | G7E-S2W-SDI | Leadtime 2-3 weeks | T5W-M63-1L | RELAY TEMP MONITOR 0-399DEG C F | K8AB-TH | Obsolete | Temperature Monitoring | - | 0°C ~ 399°C | No Delay | 100 ~ 240VAC | - | SPDT 1 Form C | 3A @ 250VAC | DIN Rail | |||||||||||||
K8AB-VS3 100 115VAC![]() | K8AB-VS3 100 115VAC | Leadtime 2-3 weeks | HF-33-Y1R | RELAY MONITOR VOLT 60-600V 120V | K8AB-VS | Obsolete | Voltage Sensing AC DC | - | 20 ~ 600V AC DC | 0.1 Sec ~ 30 Sec | 100 ~ 115VAC | Electromechanical Relay | SPDT 1 Form C | 6A @ 250VAC | DIN Rail | |||||||||||||
MXN-QH41-WE![]() | MXN-QH41-WE |
| Leadtime 2 3 weeks | UJKN-CV5-HQK | RELAY AC CUR SENS 120VAC CHAS MT | CR4395 | Active | Current Sensing AC | Latch Low | 3.0 ~ 30A AC | 2 Sec ~ 25 Sec | 120VAC | Electromechanical Relay | SPDT 1 Form C | 20A @ 240VAC | Chassis Mount | ||||||||||||
P1C-A3LA-E2E | P1C-A3LA-E2E |
| Leadtime 2-3 weeks | NWVY-FSDI-H9O | RELAY MONITOR CURRNT 2-500MA ADJ | EIL | Active | Current Sensing AC DC | Energized High | 2 ~ 500mA AC DC | 0.1 Sec ~ 3 Sec | 120VAC | Relay | SPDT 1 Form C | - | DIN Rail | ||||||||||||
V6W-XJ-16![]() | V6W-XJ-16 |
| 1 | 1SVR9-ALMY-RUU | DC FORM-A LIMIT RELAY W 2 ALARMS | TLA | Active | Temperature Monitoring | Energized High Low | -200°C ~ 1820°C | No Delay | 24VAC, 18 ~ 36VDC | - | SPST-NO 1 Form A | 5A @ 250VAC | Panel Mount | ||||||||||||
UHW-89T7-AU![]() | UHW-89T7-AU |
| Leadtime 2 3 weeks | XJU-4R5-52M | CONTROL RELAY PHASE 3X220VAC | * | Active | |||||||||||||||||||||
ALOL BNU5 ZB | ALOL BNU5 ZB |
| Leadtime 2 3 weeks | JDWN3-W7-S3A | RELAY MONITOR VOLT 0.2 60V ADJ | C Lynx | Active | Voltage Sensing AC DC | Energized High | 0.2 ~ 60V AC DC | 0.1 Sec ~ 3 Sec | 24 ~ 240VAC DC | Relay | DPDT 2 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||
IUT RDEP LC![]() | IUT RDEP LC |
| Leadtime 2 3 weeks | WLMC-WQZ6-QG | CONTROL RELAY PHASE 3X220VAC | * | Active | |||||||||||||||||||||
84871304![]() | 84871304 | 4 | 04-VVGI-9JL | HDI-L 120VAC | * | Obsolete | - | - | - | - | - | - | - | - | - | |||||||||||||
HS-O1WT-LXH![]() | HS-O1WT-LXH |
| Leadtime 2 3 weeks | 00-AUSX-5P | CONTROL RELAY UNDER VOLT 12VDC | * | Active | |||||||||||||||||||||
27H-V3NB-6U | 27H-V3NB-6U |
| Leadtime 2-3 weeks | QB-Z2F-AD | CURRENT RELAY 2 TO 500MA | K8AK | Active | Current Sensing AC DC | - | 2 ~ 500mA AC DC | 0.1 Sec ~ 30 Sec | 100 ~ 240VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||
LH-IGO-JJ![]() | LH-IGO-JJ |
| Leadtime 2-3 weeks | R65-HLS-NZR | PROCESS MONITORING | * | Active | - | - | - | - | - | - | - | - | - | ||||||||||||
UI 2MNT HN![]() | UI 2MNT HN |
| 3 | 3B9X-ZVP1-1N9 | 3 PHSE SQNCE&PHSELSS TNS PSHIN | K8DT | Active | Phase Loss, Phase Sequence | 0.1 Sec ~ 30 Sec | 380 ~ 480VAC | Solid State | NPN | DIN Rail | |||||||||||||||
QIFKQ 6I 8A0 | QIFKQ 6I 8A0 |
| Leadtime 2 3 weeks | EA2-1D-JC0 | RELAY MONITOR VOLT 0.2 60V ADJ | C Lynx | Active | Voltage Sensing AC DC | Energized High | 0.2 ~ 60V AC DC | 0.1 Sec ~ 3 Sec | 24 ~ 240VAC DC | Relay | DPDT 2 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||
3QKN-GT-NH2![]() | 3QKN-GT-NH2 |
| Leadtime 2-3 weeks | XY2PB-NB5-SMB | THIN PHSE SEQUENCE LOSS | K8DS | Active | Phase Loss, Phase Sequence | - | - | No Delay | 200 ~ 480VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||
IBO7-2EA-1F![]() | IBO7-2EA-1F |
| Leadtime 2-3 weeks | BKJZ-7P3-VF | RELAY AC CUR SENS 24VDC CHAS MT | * | Active | - | - | - | - | - | - | - | - | - | ||||||||||||
E3GY-2K3O-MH![]() | E3GY-2K3O-MH |
| Leadtime 2 3 weeks | YZI0-HEO-ZKS | EWS2 PHASE MONITOR | * | Active | |||||||||||||||||||||
NMV-JAB-N0D![]() | NMV-JAB-N0D |
| Leadtime 2-3 weeks | NQJA6-03J-RD | RELAY DC CUR SENS 24VDC CHAS MT | CR5395 | Active | Current Sensing DC | Energized Low | 3.0 ~ 30A DC | 0.5 Sec ~ 6 Sec | 24VDC | Electromechanical Relay | SPDT 1 Form C | 20A @ 240VAC | Chassis Mount | ||||||||||||
QI8G HJ2B D1V![]() | QI8G HJ2B D1V | 70 | 70-W2Q-RTO | CONTROL RELAY PHASE 3X440VAC DIN | * | Obsolete |