Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Trip Status | Trip Range | Delay Time | Voltage - Supply | Output Type | Circuit | Contact Rating @ ... | Mounting Type | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9R-IR-Z4F![]() | 9R-IR-Z4F |
| Leadtime 2-3 weeks | 0H21-RJ5Z-KIY | VLTGE CTRL RLY, 11-PIN, 24VAC | * | Active | - | - | - | - | - | - | - | - | - | ||||||||||||||
PSI0Y-6I1L-9S![]() | PSI0Y-6I1L-9S | Leadtime 2 3 weeks | XDUU-O57U-6V | EWA2 230VAC | * | Obsolete | ||||||||||||||||||||||||
XR3TK-1A-CM![]() | XR3TK-1A-CM |
| Leadtime 2-3 weeks | IF9Z-JFK-CM | DC FORM-C LIMIT RELAY W 1 ALARM | TLA | Active | Temperature Monitoring | Energized High Low | -200°C ~ 1820°C | No Delay | 24VAC, 18 ~ 36VDC | - | SPST-NO + SPDT 1 Form A + C | 5A @ 250VAC | Panel Mount | ||||||||||||||
K8DT-PH1CN | K8DT-PH1CN |
| 69 | 69Y-D5-AQ8 | 3PHSE 3WIRE PHSELSS RLY PSH IN | K8DT | Active | Phase Loss, Phase Sequence | - | - | No Delay | 200 ~ 480VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||||
K8DS-PA1![]() | K8DS-PA1 |
| Leadtime 2-3 weeks | W2K-Q0W-TA | 17.5 MM ASY PHASE SEQUENCE LO | K8DS | Active | Voltage Asymmetry, Phase Loss, Phase Sequence | - | - | 0.1 Sec ~ 30 Sec | 200 ~ 240VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||||
NOK2R-ZTU-5YI | NOK2R-ZTU-5YI |
| Leadtime 2-3 weeks | WLLF-9IG1-G5 | CRNT CTRL RLY, RELIANCE, 110VAC | IR.T | Active | Current Sensing AC | Energized High | 3.5 ~ 70.7mA, 0.035 ~ 7.07A | 0.1 Sec ~ 10 Sec | 110VAC | Relay | SPDT 1 Form C | 10A @ 250VAC | DIN Rail | ||||||||||||||
TNP-2R0N-EI![]() | TNP-2R0N-EI |
| Leadtime 2-3 weeks | BNJD-CX-V67 | EIL CRNT CTRL RLY 200-500MA 230V | EIL | Active | Current Sensing AC DC | Energized High | 2 ~ 500mA AC DC | 0.1 Sec ~ 3 Sec | 230 ~ 240VAC | Relay | SPDT 1 Form C | - | DIN Rail | ||||||||||||||
YHC-959-F9![]() | YHC-959-F9 |
| Leadtime 2-3 weeks | RSZ5-GW-OO | CIR BRKR THRM 2A | E-1048-S6 | Active | - | - | - | - | - | - | - | - | - | ||||||||||||||
Y6D-WE8C-8R8![]() | Y6D-WE8C-8R8 |
| Leadtime 2-3 weeks | IJ8M-RF1I-M3 | UNDROVRVOLT TRNS 1 -150V PSHIN | K8DT | Active | Voltage Sensing AC DC | - | 1 ~ 150V AC DC | 0.1 Sec ~ 30 Sec | 24VAC DC | Solid State | NPN | - | DIN Rail | ||||||||||||||
CR4395-EL-120-330-A-CD-ELR-I![]() | CR4395-EL-120-330-A-CD-ELR-I |
| Leadtime 2-3 weeks | SV9-MMYU-CS | RELAY AC CUR SENS 120VAC CHAS MT | CR4395 | Active | Current Sensing AC | Energized Low | 3.0 ~ 30A AC | 0.5 Sec ~ 6 Sec | 120VAC | Electromechanical Relay | SPDT 1 Form C | 20A @ 240VAC | Chassis Mount | ||||||||||||||
8227350000![]() | 8227350000 |
| Leadtime 2-3 weeks | SARQ-KH5-BCE | PROCESSOR SIGNAL 24VDC 20MA TS35 | * | Active | - | - | - | - | - | - | - | - | - | ||||||||||||||
7EKAU-H8CT-ET![]() | 7EKAU-H8CT-ET |
| 8 | 8F-YI6-N57 | OVR UNDR RELY 2-500MA PUSH IN | K8DT | Active | Current Sensing AC DC | - | 2 ~ 500mA AC DC | 0.1 Sec ~ 30 Sec | 100 ~ 240VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||||
GX40K-EZ-9WF![]() | GX40K-EZ-9WF |
| 6 | 6T8P-FH-1QE | 17.5 MM SELCT ASY PHASE-SEQU | K8DS | Active | Voltage Asymmetry, Phase Loss, Phase Sequence | - | - | 0.1 Sec ~ 30 Sec | 200 ~ 240VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||||
AYZ0-TW9-KY8![]() | AYZ0-TW9-KY8 |
| Leadtime 2 3 weeks | YG-O47X-TR | RELAY AC CUR SENS 120VAC CHAS MT | CR4395 | Active | Current Sensing AC | Energized Low | 1.0 ~ 10A AC | 2 Sec ~ 25 Sec | 120VAC | Electromechanical Relay | SPDT 1 Form C | 20A @ 240VAC | Chassis Mount | ||||||||||||||
NUFS V4 RL![]() | NUFS V4 RL |
| Leadtime 2 3 weeks | NK0M7-17Q-SS | EWS2 PHASE MONITOR | * | Active | |||||||||||||||||||||||
CR5395-EL-24D-330-B-CD-ELR-I![]() | CR5395-EL-24D-330-B-CD-ELR-I |
| 9 | 9MT-B3-KB8 | RELAY DC CUR SENS 24VDC CHAS MT | CR5395 | Active | Current Sensing DC | Energized Low | 3.0 ~ 30A DC | 2 Sec ~ 25 Sec | 24VDC | Electromechanical Relay | SPDT 1 Form C | 20A @ 240VAC | Chassis Mount | ||||||||||||||
HLUO-YX7B-7G4![]() | HLUO-YX7B-7G4 |
| 3 | 3L2-7N-QN0 | VLTGE CTRL RLY, 11-PIN, 24VAC | * | Active | - | - | - | - | - | - | - | - | - | ||||||||||||||
K8DT-AW2CD![]() | K8DT-AW2CD |
| Leadtime 2-3 weeks | H8B-HYM-E1 | OVR UNDR RELY 0.1-5A PUSH IN | K8DT | Active | Current Sensing AC DC | - | 0.1 ~ 5A AC DC | 0.1 Sec ~ 30 Sec | 24VAC DC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||||
AYOB2 Z2M IQ1![]() | AYOB2 Z2M IQ1 | Leadtime 2 3 weeks | K1IJ-CKY-9J9 | REL AC DC VOLT SENS 100 115VAC | K8AB VW | Obsolete | Voltage Sensing AC DC | 20 ~ 600V AC DC | 0.1 Sec ~ 30 Sec | 100 ~ 115VAC | Electromechanical Relay | SPDT 1 Form C Dual | 6A @ 250VAC | DIN Rail | ||||||||||||||||
ZSEO-OJ-FAX![]() | ZSEO-OJ-FAX |
| 9 | 9OFD-NL-1KL | SENSOR CURRENT 100 110 120VAC | SAO | Active | Current Sensing AC | - | - | No Delay | 100 ~ 120VAC | Relay | SPDT 1 Form C | 3A @ 240VAC | Socketable | ||||||||||||||
HDDH5-0SR-BO![]() | HDDH5-0SR-BO |
| Leadtime 2-3 weeks | T2ED-KI1Y-3VA | CURNT RELY 10 TO 200 A PUSH IN | K8DT | Active | Current Sensing AC DC | - | 10 ~ 200A AC DC | 0.1 Sec ~ 30 Sec | 100 ~ 240VAC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||||
7Y3SQ-EVNJ-JV9 | 7Y3SQ-EVNJ-JV9 |
| 98 | 98P-ZTP-ETZ | TEMP MONITORING RELAY TC RTD | K8AK | Active | Temperature Monitoring | No Delay | 24VAC DC | Relay | SPDT 1 Form C | 5A @ 250VAC | DIN Rail | ||||||||||||||||
JTK52-V7M-XSM![]() | JTK52-V7M-XSM |
| Leadtime 2-3 weeks | G3W-JD-S6 | SIGNAL CONVERTER DISCONNECTOR | * | Active | - | - | - | - | - | - | - | - | - | ||||||||||||||
UHW-89T7-AU![]() | UHW-89T7-AU |
| 4 | 4Z61-TJ-76C | CONTROL RELAY PHASE 3X220VAC | * | Active | |||||||||||||||||||||||
MQF73 TQWI KO2![]() | MQF73 TQWI KO2 | Leadtime 2 3 weeks | SZ-3B5-5CZ | TEMPERATURE MONITOR SIO RTD | * | Obsolete |