Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SEN-09403![]() | SEN-09403 |
| Leadtime 2-3 weeks | M6QCY-HXI-NX | CARBON MONOXIDE SENSOR - MQ-7 | * | Active | - | - | - | - | - | - | - | ||||||||||||||
DONLC-VYN-3C | DONLC-VYN-3C |
| Leadtime 2-3 weeks | MX-CR3-5K6 | CO2 MODULE 2000PPM DIFFUSION | Telaire® | Active | CO2 | - | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||||
110-202 | 110-202 |
| 6 | 6YZQQ-KJ7-9D0 | SENSOR GAS ALCOHOL ANALG CUR MOD | - | Active | Alcohol | - | ±3% | Current | -30°C ~ 55°C | - | - | ||||||||||||||
DY3L-KJM-5HL![]() | DY3L-KJM-5HL |
| Leadtime 2 3 weeks | UHJC-0O3-XPS | DGS ETOH DIGITAL GAS SENSOR MODU | Active | Alcohol | ±15% | USB | 20°C ~ 40°C | 2.6 V ~ 3.6 V | 4mA | ||||||||||||||||
GLSEE-YG-WS![]() | GLSEE-YG-WS |
| Leadtime 2-3 weeks | RFTS-BP7E-0NK | CARBON MONOXIDE SENSOR MQ7 | - | Active | CO2 | - | - | 0 V ~ 5 V | -20°C ~ 50°C | 5V | - | ||||||||||||||
U0-0GV-X1![]() | U0-0GV-X1 | 1 | 1QCK-9MTW-66 | IR SENSOR HEAD FOR 0-5% 100% HC | - | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
VI-JBIE-V34![]() | VI-JBIE-V34 |
| 333 | 333-RG-XT | CO2 TRANSMITTER INDUCT MOUNT 0-5 | Ventostat® | Active | CO2 | - | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA | ||||||||||||||
ILFE-ILZE-JC![]() | ILFE-ILZE-JC |
| 7 | 07L-81-HW | CO2 SENSOR DUCT MOUNT 0-10V OUT | - | Active | CO2 | - | 3% | 0 V ~ 5 V, 0 V ~ 10 V Selectable | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | - | ||||||||||||||
FMM-P50-US![]() | FMM-P50-US |
| 6 | 6DB3W-KZV2-NT | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 0 V ~ 10 V | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
EI6-ZWO-EX![]() | EI6-ZWO-EX |
| 40 | 40W-L7-7PE | GAS SENSOR -MQ5 | * | Active | Natural Gas, Propane | - | - | - | -10°C ~ 50°C | 5V | - | ||||||||||||||
ST-HJ4-JZN![]() | ST-HJ4-JZN |
| 4 | 4SR-LC-Z2 | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
XC-601P-XI![]() | XC-601P-XI |
| Leadtime 2-3 weeks | JQQG-EXJI-42 | SENSOR NITR DIOX ANALOG VLTG MOD | - | Active | Nitrogen Dioxide | - | ±2% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
IR604 3![]() | IR604 3 | Leadtime 2-3 weeks | ZEO6-9H-B0L | IR SENSOR HEAD FOR 0-100% LEL AC | - | Active | Acetylene | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
DR-IFN9-3V5![]() | DR-IFN9-3V5 |
| Leadtime 2-3 weeks | HK5K-IZ1-A7T | MOD IAQ I2C CONTINUOUS MODE | - | Active | Air Quality | - | - | I²C | 0°C ~ 50°C | 3.3V | 2.7mA | ||||||||||||||
EL-066K-41 | EL-066K-41 |
| Leadtime 2-3 weeks | JBV4-NA05-X9 | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA | ||||||||||||||
UY-ME-NB![]() | UY-ME-NB | Leadtime 2-3 weeks | DEG9B-3A-K47 | 19MM, 0-5% CO2 AND 0-5% 100% HC | - | Active | CO2, Methane | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
WG-L1M5-KW5![]() | WG-L1M5-KW5 | 8 | 8GHUO-IJ-H4 | 19MM, 0-5% VOLUME CO2 INFRARED G | - | Active | Hydro Generator | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
0Y-BO1-GT![]() | 0Y-BO1-GT |
| Leadtime 2 3 weeks | QUYLH-E5G5-JH | CARBON MONOXIDE SENSOR MQ7 | Active | CO2 | 0 V ~ 5 V | 20°C ~ 50°C | 5V | ||||||||||||||||||
110-303![]() | 110-303 |
| Leadtime 2-3 weeks | MO-8YJN-BGU | SENS GAS HYD SULF ANALG CUR MOD | - | Active | Hydrogen Sulfide | - | ±3% | Current | -30°C ~ 55°C | - | - | ||||||||||||||
EF-NFJ-HX![]() | EF-NFJ-HX | Leadtime 2 3 weeks | MTSNN-24CL-ZPN | INTEGRATED INFRARED CO2 GAS SENS | Active | Air Quality | Voltage | 40°C ~ 75°C | 3.2 V ~ 5 V | 35mA | ||||||||||||||||||
NZC7L-UK-H9 | NZC7L-UK-H9 |
| Leadtime 2-3 weeks | LANF-STYL-12 | SENSOR GAS CO ANALOG CUR MOD | - | Active | Carbon Monoxide | - | ±2% | Current | -30°C ~ 55°C | 5mV | - | ||||||||||||||
YISU-66N-52![]() | YISU-66N-52 |
| Leadtime 2 3 weeks | XEGMK-M41-W1 | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 0 V ~ 10 V | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
HZCIF-QH-H8![]() | HZCIF-QH-H8 |
| Leadtime 2-3 weeks | TG-GL-SX1 | SENS GAS HYD SULF ANALG CUR MOD | - | Active | Hydrogen Sulfide | - | ±3% | Current | -30°C ~ 55°C | - | - | ||||||||||||||
UEG-CSR8-XQ![]() | UEG-CSR8-XQ |
| Leadtime 2-3 weeks | GLS1-O0Y-N6D | MOD IAQ I2C CONTINUOUS MODE | - | Active | Air Quality | - | - | I²C | 0°C ~ 50°C | 3.3V | 2.7mA | ||||||||||||||
64M NK QKK![]() | 64M NK QKK |
| Leadtime 2 3 weeks | BBD2-DN-741 | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 4mA ~ 20mA | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA |