Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4K-4J-279![]() | 4K-4J-279 |
| Leadtime 2 3 weeks | BTR-LI-I7 | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 0 V ~ 10 V | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
SELWJ-ME6-IK![]() | SELWJ-ME6-IK | Leadtime 2 3 weeks | 0V2V-TKM-YQU | HPM SERIES PM2.5 PARTICLE SENSOR | HPM | Active | Air Quality | ±15% | UART | 10°C ~ 50°C | 5V | 80mA | ||||||||||||||||
VI-JBIE-V34![]() | VI-JBIE-V34 |
| Leadtime 2-3 weeks | C3YGO-12-6RT | CO2 TRANSMITTER INDUCT MOUNT 0-5 | Ventostat® | Active | CO2 | - | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA | ||||||||||||||
T8200-D![]() | T8200-D |
| Leadtime 2-3 weeks | PHCI-UZG3-RM | CO2 TEMP SENS WALL MNT DUAL OUT | T8000 | Active | CO2 | - | ±5% | 0 V ~ 5 V, 0 V ~ 10 V Selectable | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | 4 ~ 20mA | ||||||||||||||
MF010-1-LC4![]() | MF010-1-LC4 |
| Leadtime 2-3 weeks | NYEW1-NJ-U3 | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 4mA ~ 20mA | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
I2TSM-L0-1LK![]() | I2TSM-L0-1LK | Leadtime 2-3 weeks | CO-TO-LRY | SENSOR OXYGEN 24V 500MA | MF010 | 0 | Oxygen | 1 mbar ~ 250 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | |||||||||||||||
EYQ0-K4V-3Y![]() | EYQ0-K4V-3Y |
| Leadtime 2-3 weeks | JT-W23-SQ | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 4mA ~ 20mA | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
8RD-O9-UW![]() | 8RD-O9-UW |
| Leadtime 2 3 weeks | L8-P2M6-AWE | SENSOR HYD SULF ANALOG VLTG MOD | Active | Hydrogen Sulfide | ±2% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||||
IR12GJ![]() | IR12GJ | Leadtime 2-3 weeks | Q1YUM-K4F-WJ | 19MM, HYDROCARBON INFRARED GAS S | - | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
DE-23E-DK0![]() | DE-23E-DK0 |
| Leadtime 2 3 weeks | T56P1-P6-U8 | SENSOR ALCOHOL ANALOG VLTG MOD | Active | Alcohol | ±3% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||||
110-401![]() | 110-401 |
| Leadtime 2-3 weeks | OD-CAG-JBP | SENSOR GAS OZONE ANALOG CUR MOD | - | Active | Ozone | - | ±3% | Current | -30°C ~ 50°C | - | - | ||||||||||||||
266FP-H5V-CU![]() | 266FP-H5V-CU |
| Leadtime 2-3 weeks | K4O-OS84-VBT | KGZ-12 HIGH-ACCURACY OXYGEN | - | Active | Oxygen | 2 mbar ~ 3 bar | < 5 mbar | Voltage | 700°C | 4V | 40mA | ||||||||||||||
T6613-F | T6613-F |
| Leadtime 2-3 weeks | XGXJN-DX-YA | CO2 MODULE 2000PPM FLOW THROUGH | Telaire® | Active | CO2 | - | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||||
MF010-2-LC1![]() | MF010-2-LC1 |
| 8 | 8STE-0JIK-P5Q | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
HH-SZ9F-I19![]() | HH-SZ9F-I19 | Leadtime 2-3 weeks | SGP-NHN-29 | IR SENSOR HEAD FOR 0-5% 100% BRO | - | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
C0R0T-9MRY-9TO![]() | C0R0T-9MRY-9TO | Leadtime 2-3 weeks | XE57H-C2G6-BD | 19MM, 0-5% VOLUME CO2 INFRARED G | - | Active | Hydro Generator | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
D1-3X7J-INZ![]() | D1-3X7J-INZ | Leadtime 2-3 weeks | NRR1E-0K8-ZD | VQ21 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
0D6ZO-7W-TDS | 0D6ZO-7W-TDS |
| 4 | 4U1-8FI-DBY | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA | ||||||||||||||
CCS801B-COPD-2![]() | CCS801B-COPD |
| Leadtime 2-3 weeks | ES0D1-XLT-35X | GAS SENSOR | - | Active | Air Quality | - | - | Voltage | -5°C ~ 50°C | 1.4V | - | ||||||||||||||
Z5 QYQ 3UN | Z5 QYQ 3UN |
| Leadtime 2 3 weeks | GZO-AA7R-KV | CARBON MONOXIDE GAS SENSOR | Active | Carbon Monoxide | 0 V ~ 5 V | 20°C ~ 50°C | 5V | 160mA | |||||||||||||||||
VQ606M 1![]() | VQ606M 1 | 1 | 1G9-AKV-58 | VQ6 PELLISTOR, VQ600 HEAD, METRI | VQ600 | Active | Light Gases | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
ILFE-ILZE-JC![]() | ILFE-ILZE-JC |
| Leadtime 2-3 weeks | HY8Q-DKI-Z1M | CO2 SENSOR DUCT MOUNT 0-10V OUT | - | Active | CO2 | - | 3% | 0 V ~ 5 V, 0 V ~ 10 V Selectable | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | - | ||||||||||||||
HG-96S-6O4![]() | HG-96S-6O4 | Leadtime 2-3 weeks | L0-B0BB-JF | VQ31 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Light Gases | - | - | Voltage | -20°C ~ 60°C | 3.5V | 90mA | |||||||||||||||
UEG-CSR8-XQ![]() | UEG-CSR8-XQ |
| 9 | 9AG-5MJ0-JX | MOD IAQ I2C CONTINUOUS MODE | - | Active | Air Quality | - | - | I²C | 0°C ~ 50°C | 3.3V | 2.7mA | ||||||||||||||
VEAB-EN-JJ | VEAB-EN-JJ |
| Leadtime 2-3 weeks | GK-97-D6X | CO2 MODULE 2000PPM W GAS PORTS | Telaire® | Active | CO2 | - | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - |