Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWJ S1 0N![]() | AWJ S1 0N | Leadtime 2 3 weeks | YPBYX-9O-12 | CO2 TEMP SENSOR WALL MNT 0 10V | T5000 | Obsolete | CO2 | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC | |||||||||||||||
IRI-3I6-WM![]() | IRI-3I6-WM |
| 2 | 2PE-9YM8-AE | DGS-RESPIRR DIGITAL GAS SENSOR M | - | Active | Nitrogen Dioxide | - | ±15% | USB | -20°C ~ 40°C | 2.6 V ~ 3.6 V | 4mA | ||||||||||||
VQ621T 2![]() | VQ621T 2 | Leadtime 2-3 weeks | O556-18VB-H8 | VQ21 PELLISTOR, VQ600 HEAD, 0.5 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||
T5003![]() | T5003 | Leadtime 2-3 weeks | H4-OND-WJZ | CO2 TEMP SENSOR WALL MNT 0-10V | T5000 | Obsolete | CO2 | - | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC | - | |||||||||||||
NCXM1-S7P3-E3![]() | NCXM1-S7P3-E3 |
| 4 | 4WBY-24L-D5B | SENSOR NITR DIOX ANALOG VLTG MOD | Active | Nitrogen Dioxide | ±2% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
3OAR-AEV-HOF![]() | 3OAR-AEV-HOF |
| Leadtime 2-3 weeks | IKKQZ-NUOY-9P9 | KGZ-12 HIGH-ACCURACY OXYGEN | - | Active | Oxygen | 2 mbar ~ 3 bar | < 5 mbar | Voltage | 700°C | 4V | 40mA | ||||||||||||
DY3L-KJM-5HL![]() | DY3L-KJM-5HL |
| Leadtime 2 3 weeks | GPHI-4O-QS | DGS ETOH DIGITAL GAS SENSOR MODU | Active | Alcohol | ±15% | USB | 20°C ~ 40°C | 2.6 V ~ 3.6 V | 4mA | ||||||||||||||
T6615 | T6615 |
| 98 | 98B-0R-BQ0 | CO2 MODULE 2000PPM DIFFUSION | Telaire® | Active | CO2 | - | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||
5H1 Y7I UX | 5H1 Y7I UX |
| Leadtime 2 3 weeks | YD89-HFX-FN4 | PROPANE GAS SENSOR | Active | Propane | 0 V ~ 5 V | 10°C ~ 50°C | 5V | 160mA | |||||||||||||||
GR7IN-Z5HC-WN![]() | GR7IN-Z5HC-WN |
| Leadtime 2 3 weeks | GG-BMX-VD6 | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 4mA ~ 20mA | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||
NXLY-QH4-KU![]() | NXLY-QH4-KU | 1 | 1WIQO-EA6-NHX | IR SENSOR HEAD FOR 0 5% 100% BRO | Active | Hydrocarbons | Voltage | 20°C ~ 60°C | 5V | 60mA | ||||||||||||||||
G88A-QV-5TS![]() | G88A-QV-5TS | Leadtime 2-3 weeks | DB-ISIA-E8 | 19MM, 0-100% LEL ACETYLENE INFRA | - | Active | Acetylene | - | ±5% | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 60mA | |||||||||||||
PB-LR5-7PY![]() | PB-LR5-7PY | Leadtime 2-3 weeks | XH5EI-2XF6-DAF | VQ22 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 175mA | |||||||||||||
T6615-10K![]() | T6615-10K |
| 6 | 6QO-AHV7-KCB | CO2 MODULE 10000PPM DIFFUSION | - | Active | CO2 | - | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||
AS-MLV-P2 | AS-MLV-P2 |
| Leadtime 2-3 weeks | A5GZ-TA-RXZ | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA | ||||||||||||
VQ635M 2![]() | VQ635M 2 | 7 | 7A62-7GBF-48 | VQ35 PELLISTOR, VQ600 HEAD, 0.5 | VQ600 | Active | Light Gases | - | - | Voltage | -20°C ~ 60°C | 4.2V | 55mA | |||||||||||||
35C-62M-K9![]() | 35C-62M-K9 | Leadtime 2 3 weeks | DT4-1ZQ-N1B | SERIES 2, 16MM, 0 TO 5% CO2 IR S | Active | CO2 | ±0.5% | Voltage | 20°C ~ 60°C | 3 V ~ 5 V | 60mA | |||||||||||||||
CG3Z-098-JHO![]() | CG3Z-098-JHO | Leadtime 2-3 weeks | TD-KR7-2U | PR PELLISTOR PAIR 2V 175MA OC SO | VQ20 | Active | Hydrocarbons | - | - | Voltage | - | 2V | 175mA | |||||||||||||
1T8R RTY5 1Y![]() | 1T8R RTY5 1Y |
| Leadtime 2 3 weeks | HGLM-640V-QX | CO2 MODULE 50000PPM FLOW THROUGH | Active | CO2 | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | |||||||||||||||
605-00011 | 605-00011 |
| Leadtime 2-3 weeks | X5-L53-O1 | ALCOHOL BENZINE GAS SENSOR | - | Active | Alcohol, Benzine | - | - | 0 V ~ 5 V | -10°C ~ 50°C | 5V | 160mA | ||||||||||||
7X-0EEA-6C![]() | 7X-0EEA-6C | Leadtime 2-3 weeks | ZR8-H0H-OA | IR SENSOR HEAD FOR 0-5% 100% BRO | - | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||
DEV8-ESV2-G81![]() | DEV8-ESV2-G81 |
| Leadtime 2 3 weeks | SY84L-BN7-PKO | SENSOR AIR QUAL ANALOG VLTG MOD | Active | Air Quality | ±2% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
KYGPP-3I6-4DA![]() | KYGPP-3I6-4DA |
| Leadtime 2-3 weeks | FBRDO-CB-K0V | SENSOR GAS CO2 ANALOG VLTG MOD | - | Active | Carbon Monoxide | - | ±3% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||
2F H4 SZ![]() | 2F H4 SZ |
| Leadtime 2 3 weeks | S6-8Z7-A3 | CO2 TRANSMITTER INDUCT MOUNT 0 5 | Ventostat® | Active | CO2 | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA | |||||||||||||
QS-IQ5U-ZD![]() | QS-IQ5U-ZD |
| Leadtime 2-3 weeks | J944-U5Z-M49 | SENSOR NITR DIOX ANALOG VLTG MOD | - | Active | Nitrogen Dioxide | - | ±2% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA |