Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P2-1FG-CG![]() | P2-1FG-CG |
| Leadtime 2-3 weeks | BP1BY-FJV9-Z3 | CO2 TRANSMITTER INDUCT MOUNT 0-1 | Ventostat® | Active | CO2 | - | ±5% | 0 V ~ 10 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA | ||||||||||||||
CH-AZ8C-HPU![]() | CH-AZ8C-HPU |
| 2 | 2XQ-J6N-KR | SENS GAS AIR QUAL ANALG CUR MOD | - | Active | Air Quality | - | - | Current | -10°C ~ 40°C | - | - | ||||||||||||||
IR14BD![]() | IR14BD | Leadtime 2-3 weeks | A5AQ-N8-JL3 | 19MM, 0-100% LEL ACETYLENE INFRA | - | Active | Acetylene | - | ±5% | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 60mA | |||||||||||||||
UJEYK-GOW-IJV![]() | UJEYK-GOW-IJV |
| Leadtime 2-3 weeks | O34-ZB-ZY | SENSOR GAS CO2 ANALOG VLTG MOD | - | Active | Carbon Monoxide | - | ±3% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
80-5JU-U5 | 80-5JU-U5 | Leadtime 2-3 weeks | HLMJ2-SQ72-BQ | CARBON DIOXIDE GAS SENSOR | - | Obsolete | Gas, Carbon Dioxide | - | - | 30 mV ~ 50 mV | -20°C ~ 50°C | 6.5 V ~ 12 V | 160mA | |||||||||||||||
MF010-0-LC3 | MF010-0-LC3 |
| 8 | 8P-A7W-MJ | SENSOR OXYGEN 24V 500MA | MF010 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 4mA ~ 20mA | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
QQQRH-TTZ-7D![]() | QQQRH-TTZ-7D |
| Leadtime 2-3 weeks | XI-DNPS-5V | SENS GAS AIR QUAL ANALG CUR MOD | - | Active | Air Quality | - | - | Current | -10°C ~ 40°C | - | - | ||||||||||||||
T6713-5K | T6713-5K |
| Leadtime 2-3 weeks | U4-XM-DA | CO2 MODULE 5000PPM DIFFUSION | Telaire® | Active | CO2 | - | ±2% | I²C | 14 ~ 140°F -10 ~ 60°C | 4.5 V ~ 5.5 V | 200mA | ||||||||||||||
T5003![]() | T5003 | 407 | 407C-U1YS-DMU | CO2 TEMP SENSOR WALL MNT 0-10V | T5000 | Obsolete | CO2 | - | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC | - | |||||||||||||||
P04QJ-H4V-VWY![]() | P04QJ-H4V-VWY | 87 | 87YYW-FBA6-C6 | VQ21 PELLISTOR VQ600 HEAD, METRI | VQ600 | Active | Hydrocarbons | Voltage | 20°C ~ 60°C | 2V | 300mA | |||||||||||||||||
T5007![]() | T5007 | Leadtime 2-3 weeks | UC4-AAJ-GL | CO2 TEMP SENSOR WALL MNT 0-10V | T5000 | Obsolete | CO2 | - | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC | - | |||||||||||||||
D1-3X7J-INZ![]() | D1-3X7J-INZ | Leadtime 2-3 weeks | FOP-FB-N6 | VQ21 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
PHVSM-2RK-PX6![]() | PHVSM-2RK-PX6 | Leadtime 2-3 weeks | XJLKC-851-JG | 16MM, HYDROCARBON INFRARED GAS S | - | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | - | |||||||||||||||
XVQWR-4243-IA![]() | XVQWR-4243-IA | Leadtime 2-3 weeks | Y7DZ-SI-NRP | IR SENSOR HEAD FOR 0-100% LEL AC | - | Active | Acetylene | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
5M-RI-XM8![]() | 5M-RI-XM8 |
| 60 | 60EB-4U9-Z2D | SENSOR AIR QUAL ANALOG VLTG MOD | - | Active | Air Quality | - | ±2% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||
IR15TT-R![]() | IR15TT-R | Leadtime 2-3 weeks | MEQP-1XF0-EJ | 0-100% CH4 & CO2 IR GAS SENSOR F | - | Active | CO2, Methane | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
MF010-0-LC2 | MF010-0-LC2 |
| Leadtime 2-3 weeks | NX-67D-A0K | SENSOR OXYGEN 24V 500MA | MF010 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
VQ635M 2![]() | VQ635M 2 | 7 | 7RVNO-9HN-XO | VQ35 PELLISTOR, VQ600 HEAD, 0.5 | VQ600 | Active | Light Gases | - | - | Voltage | -20°C ~ 60°C | 4.2V | 55mA | |||||||||||||||
E6I-19M-PP![]() | E6I-19M-PP | Leadtime 2-3 weeks | SYAP-PA-9P | IR SENSOR HEAD FOR 0-5%CO2 - M20 | - | Active | CO2 | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA | |||||||||||||||
LJF7-92C-RV![]() | LJF7-92C-RV |
| Leadtime 2-3 weeks | UF04-O60-AD | IAQ-ENGINE MODULE LF I2C & 0-5V- | - | Last Time Buy | Air Quality | - | - | I²C | 0°C ~ 50°C | 4.75 ~ 5.25 V | 45mA | ||||||||||||||
VI-JBIE-V34![]() | VI-JBIE-V34 |
| Leadtime 2-3 weeks | V0C9K-CW4-MWL | CO2 TRANSMITTER INDUCT MOUNT 0-5 | Ventostat® | Active | CO2 | - | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA | ||||||||||||||
UY-ME-NB![]() | UY-ME-NB | Leadtime 2-3 weeks | QD-YFS-M35 | 19MM, 0-5% CO2 AND 0-5% 100% HC | - | Active | CO2, Methane | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
2V-LYC-IS![]() | 2V-LYC-IS | Leadtime 2-3 weeks | 0I-99VR-8HL | VQ21 PELLISTOR, VQ600 HEAD, 0.5 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
RVH09-2KUZ-LQ1![]() | RVH09-2KUZ-LQ1 | Leadtime 2 3 weeks | GJ2-7ZA-EM | HPM SERIES PM2.5 PARTICLE SENSOR | HPM | Active | Air Quality | ±15% | UART | 10°C ~ 50°C | 5V | 80mA | ||||||||||||||||
RE-TWW-5M0![]() | RE-TWW-5M0 |
| 2 | 2L8VC-KSE1-1GS | CO2 MODULE 2000PPM DIFFUSION | - | Active | CO2 | - | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - |