Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GR-RE-69R![]() | GR-RE-69R |
| Leadtime 2-3 weeks | RNC-4BE-P9W | LOW POWER DIGITAL SENSOR FOR IND | - | Active | Air Quality | - | - | I²C | -5°C ~ 50°C | 1.8 V ~ 3.6 V | 26mA | ||||||||||||||
AF6N-LVZ-D72![]() | AF6N-LVZ-D72 | Leadtime 2-3 weeks | XH7UE-WT-TC | VQ21 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
7BX-0ANL-M6![]() | 7BX-0ANL-M6 |
| Leadtime 2 3 weeks | DP80O-VSTZ-OA | CO2 MODULE 2000PPM DIFFUSION | Active | CO2 | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | |||||||||||||||||
QO-N6W-JQ![]() | QO-N6W-JQ | Leadtime 2-3 weeks | JNH-GNR-IO | VQ21 PELLISTOR VQ600 HEAD, METRI | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
040-HM-E9L![]() | 040-HM-E9L | Leadtime 2 3 weeks | M31-32GH-NH | PR PELLISTOR PAIR 2V 175MA OC SO | VQ20 | Active | Hydrocarbons | Voltage | 2V | 175mA | ||||||||||||||||||
314100010![]() | 314100010 |
| 5 | 5PC-6AB-4GB | GAS SENSOR -MQ5 | * | Active | Natural Gas, Propane | - | - | - | -10°C ~ 50°C | 5V | - | ||||||||||||||
37PN-QFR-VXD![]() | 37PN-QFR-VXD |
| Leadtime 2 3 weeks | B385-R3BE-YG | SENSOR ALCOHOL ANALOG VLTG MOD | Active | Alcohol | ±3% | 0 V ~ 3 V | 40°C ~ 50°C | 2.7 V ~ 3.3 V | 15µA | ||||||||||||||||
GO0N0-TS8T-690![]() | GO0N0-TS8T-690 |
| 7 | 7KFUG-GK-5I2 | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 0 V ~ 10 V | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
AS-MLV-P2-1 | AS-MLV-P2 |
| Leadtime 2-3 weeks | M9UP-RD-G2F | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA | ||||||||||||||
8MCI-OK4C-DA![]() | 8MCI-OK4C-DA |
| Leadtime 2-3 weeks | M5OVB-1CY-Q3V | CO2 TEMP SENS WALL MNT DUAL OUT | T8000 | Active | CO2 | - | ±5% | 0 V ~ 5 V, 0 V ~ 10 V Selectable | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | 4 ~ 20mA | ||||||||||||||
LWAR-VV-5V | LWAR-VV-5V |
| Leadtime 2-3 weeks | B31TT-I7HO-XH3 | CO2 MODULE 2000PPM DIFFUSION | Telaire® | Active | CO2 | - | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||||
110-801![]() | 110-801 |
| 6 | 6I-V75M-1C4 | SENS GAS AIR QUAL ANALG CUR MOD | - | Active | Air Quality | - | - | Current | -10°C ~ 40°C | - | - | ||||||||||||||
FV-CCX-QS![]() | FV-CCX-QS |
| Leadtime 2-3 weeks | G6B-I1S-Q73 | GAS SENSOR -MQ5 | * | Active | Natural Gas, Propane | - | - | - | -10°C ~ 50°C | 5V | - | ||||||||||||||
110-401![]() | 110-401 |
| Leadtime 2-3 weeks | Z4RM-IB9M-S8B | SENSOR GAS OZONE ANALOG CUR MOD | - | Active | Ozone | - | ±3% | Current | -30°C ~ 50°C | - | - | ||||||||||||||
05S-Z1E-2V![]() | 05S-Z1E-2V |
| Leadtime 2-3 weeks | B9R-2PT-67E | DGS-RESPIRR DIGITAL GAS SENSOR M | - | Active | Nitrogen Dioxide | - | ±15% | USB | -20°C ~ 40°C | 2.6 V ~ 3.6 V | 4mA | ||||||||||||||
110-303![]() | 110-303 |
| 826 | 826X-IO1T-IBD | SENS GAS HYD SULF ANALG CUR MOD | - | Active | Hydrogen Sulfide | - | ±3% | Current | -30°C ~ 55°C | - | - | ||||||||||||||
VWR-BIBP-D1V![]() | VWR-BIBP-D1V |
| Leadtime 2 3 weeks | N39F-Y5B1-GO | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 4mA ~ 20mA | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
EL-066K-41 | EL-066K-41 |
| Leadtime 2-3 weeks | A2-WN-14X | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA | ||||||||||||||
36M-CI-LG8![]() | 36M-CI-LG8 | Leadtime 2 3 weeks | OZA-LL-ELM | PR PELLISTOR PR, 2V 300MA OC SOL | VQ20 | Active | Hydrocarbons | Voltage | 2V | 300mA | ||||||||||||||||||
BC1 T2E 4Q6![]() | BC1 T2E 4Q6 |
| 8 | 8LW4J-7TC-ACQ | CO2 MODULE W HEADER FOR AAS AQS | Active | CO2 | ±3% | I²C, PWM | 10°C ~ 60°C | 4.5 V ~ 5.5 V | 25mA | ||||||||||||||||
B2-RH-VAY![]() | B2-RH-VAY | Leadtime 2-3 weeks | T1-FYF1-ID | SMOKE SENSOR | * | Obsolete | Alcohol, Butane, Hydrogen, Methane, Propane | - | - | - | -20°C ~ 50°C | 5V | - | |||||||||||||||
L2P-YJ-8T2![]() | L2P-YJ-8T2 | Leadtime 2-3 weeks | 0U-6K8-3O | 16MM, 0-5% VOLUME CO2 INFRARED G | - | Active | CO2 | - | - | Voltage | -20°C ~ 55°C | 3 V ~ 5 V | 35mA | |||||||||||||||
SL-RC5N-48![]() | SL-RC5N-48 | Leadtime 2-3 weeks | SL5A-4T-1S | PELLISTOR PR 3.5V 90MA TC C CAN | VQ30 | Active | Hydrocarbons | - | - | Voltage | - | 2 V ~ 3.45 V | 100mA | |||||||||||||||
QHVR-AW-66 | QHVR-AW-66 |
| 9 | 9KK-83-D2A | SENSOR GAS CO ANALOG CUR MOD | - | Active | Carbon Monoxide | - | ±2% | Current | -30°C ~ 55°C | 5mV | - | ||||||||||||||
NNK-BK-3JP![]() | NNK-BK-3JP |
| Leadtime 2-3 weeks | FDCKT-1O-ILL | MF010 LOW TEMP OXYGEN SENSOR | MF010 | Active | Oxygen | 1 mbar ~ 250 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA |