Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature ... | Voltage - Supply | Current - Supply | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AS-MLV-P2-2 | AS-MLV-P2 |
| Leadtime 2-3 weeks | S1CY-XEH-DQ | MOD MEMS GAS SENSOR VOC TO39 | - | Active | Air Quality | - | - | Voltage | 0°C ~ 50°C | 3V | 25mA | ||||||||||||||
F4OTK-0AQ-51![]() | F4OTK-0AQ-51 |
| Leadtime 2-3 weeks | IO7-W4LP-HPC | GAS SENSOR -MQ5 | * | Active | Natural Gas, Propane | - | - | - | -10°C ~ 50°C | 5V | - | ||||||||||||||
IR21EM![]() | IR21EM | 30 | 30Y-V4-QCU | SERIES 2, 16MM, 0 TO 5% CO2 IR S | - | Active | CO2 | - | ±0.5% | Voltage | -20°C ~ 60°C | 3 V ~ 5 V | 60mA | |||||||||||||||
M7XPH-DZ-H4B![]() | M7XPH-DZ-H4B | Leadtime 2-3 weeks | QSWVZ-34O-6EK | VQ1 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Air Quality | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
CZZ-HE-90![]() | CZZ-HE-90 | 5 | 5BU9-P7-QC9 | SERIES 2, 19MM, 0 5% CO2 IR SENS | Active | CO2 | ±0.5% | Voltage | 20°C ~ 60°C | 3 V ~ 5 V | 60mA | |||||||||||||||||
T6613-C | T6613-C |
| 4 | 4B-3PR0-PJ7 | CO2 MODULE 2000PPM W GAS PORTS | Telaire® | Active | CO2 | - | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - | ||||||||||||||
TCU0Y XZL KVR![]() | TCU0Y XZL KVR | Leadtime 2 3 weeks | UXJ17-7EK-57F | VQ47 AMMONIA SENSOR, VQ500 HEAD | VQ500 | Active | Hydrocarbons | Voltage | 40°C ~ 55°C | 3 V ~ 4.2 V | 60mA | |||||||||||||||||
B5O19-R0-NT7![]() | B5O19-R0-NT7 | 8 | 8Z-0HWL-95 | VQ5 PELLISTOR, VQ600 HEAD, METRI | VQ600 | Active | Light Gases | - | - | Voltage | -20°C ~ 60°C | 2V | 175mA | |||||||||||||||
CCS801B-COPR![]() | CCS801B-COPR |
| 7 | 7S-MG3W-JZD | GAS SENSOR | - | Active | Air Quality | - | - | Voltage | -5°C ~ 50°C | 1.8V | - | ||||||||||||||
64-YT-VS2![]() | 64-YT-VS2 |
| Leadtime 2 3 weeks | OBI-MTK6-U7 | CO2 MODULE 2000PPM DIFFUSION | Active | CO2 | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | |||||||||||||||||
GUJ-MA-AC5![]() | GUJ-MA-AC5 | 3 | 3HH-LW-IZ | VQ22 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 175mA | |||||||||||||||
DGI-79-13W![]() | DGI-79-13W |
| Leadtime 2-3 weeks | ZB-HGN-AF | MOD IAQ I2C CONTINUOUS MODE | - | Active | Air Quality | - | - | I²C | 0°C ~ 50°C | 3.3V | 2.7mA | ||||||||||||||
IL3Y4-ZX6-XG![]() | IL3Y4-ZX6-XG |
| Leadtime 2-3 weeks | C7-AA-JFA | KGZ-12 HIGH-ACCURACY OXYGEN | - | Active | Oxygen | 2 mbar ~ 3 bar | < 5 mbar | Voltage | 700°C | 4V | 40mA | ||||||||||||||
3B6-PI9-10![]() | 3B6-PI9-10 |
| Leadtime 2-3 weeks | S5S21-4F-W4A | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 0 V ~ 10 V | -10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
OBIG-PV-P0![]() | OBIG-PV-P0 | 95 | 95IG-2MI-1U | INTEGRATED INFRARED CH4 GAS SENS | * | Active | - | - | - | - | - | - | - | |||||||||||||||
CG3Z-098-JHO![]() | CG3Z-098-JHO | Leadtime 2-3 weeks | D2FNS-H09-YY5 | PR PELLISTOR PAIR 2V 175MA OC SO | VQ20 | Active | Hydrocarbons | - | - | Voltage | - | 2V | 175mA | |||||||||||||||
4WBRK-1U7B-B1![]() | 4WBRK-1U7B-B1 | Leadtime 2-3 weeks | V8GI6-5ECO-AZ0 | LOW POWER SENSOR FOR ETHANOL DET | - | Last Time Buy | Alcohol | - | - | Voltage | -5°C ~ 50°C | 1.5 V ~ 3.3 V | - | |||||||||||||||
266FP-H5V-CU![]() | 266FP-H5V-CU |
| Leadtime 2-3 weeks | AQ9T-LEP-0OA | KGZ-12 HIGH-ACCURACY OXYGEN | - | Active | Oxygen | 2 mbar ~ 3 bar | < 5 mbar | Voltage | 700°C | 4V | 40mA | ||||||||||||||
ILFE-ILZE-JC![]() | ILFE-ILZE-JC |
| Leadtime 2-3 weeks | L9E-DXA-LES | CO2 SENSOR DUCT MOUNT 0-10V OUT | - | Active | CO2 | - | 3% | 0 V ~ 5 V, 0 V ~ 10 V Selectable | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | - | ||||||||||||||
VQ622T 3![]() | VQ622T 3 | Leadtime 2-3 weeks | UY-Q7X-NY | VQ22 PELLISTOR, VQ600 HEAD, 0.75 | VQ600 | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 175mA | |||||||||||||||
V2IPY XPH FKZ![]() | V2IPY XPH FKZ |
| 5 | 5N4AY-YOIP-L9 | MF010 HIGH TEMP OXYGEN SENSOR | MF020 | Active | Oxygen | 1 mbar ~ 1000 mbar | ±2% | 4mA ~ 20mA | 10°C ~ 50°C | 22.8 V ~ 25.2 V | 500mA | ||||||||||||||
P2-1FG-CG![]() | P2-1FG-CG |
| 8 | 8CPG1-YA-Y5J | CO2 TRANSMITTER INDUCT MOUNT 0-1 | Ventostat® | Active | CO2 | - | ±5% | 0 V ~ 10 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA | ||||||||||||||
VQ601 1![]() | VQ601 1 | Leadtime 2-3 weeks | OPLRO-JR-PG | VQ1 PELLISTOR, VQ600 HEAD, METRI | VQ600 | Active | Air Quality | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA | |||||||||||||||
110-602![]() | 110-602 |
| Leadtime 2-3 weeks | 0V1-MSZ5-6B | SENS GAS SULF DIOX ANALG CUR MOD | - | Active | Sulfur Dioxide | - | ±3% | Current | -30°C ~ 50°C | - | - | ||||||||||||||
SP-HBR6-MK0![]() | SP-HBR6-MK0 |
| 7 | 7O-HWT-NB | CO2 TRANSMITTER INDUCT MOUNT 0-5 | Ventostat® | Active | CO2 | - | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18 V ~ 40 V | 40mA |