ManufacturerSeriesPart StatusRelay TypeFunctionCircuitDelay TimeOutput TypeContact Rating @ VoltageVoltage - SupplyMounting TypeTermination StyleTiming Adjustment MethodTiming Initiate Method
Supplier Part Number
Manufacturer Part Number
PriceStock
Manufacturer
Description
Series
Part Status
Relay Type
Function
Circuit
Delay Time
Output Type
Contact Rating @ ...
Voltage - Supply
Mounting Type
Termination Style
Timing Adjustment ...
Timing Initiate Method ...
88226014
88226014
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-230VAC-50HZ 12HR PANE*Active-----------
88226013
88226013
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-24VAC-50HZ 12M PANEL*Active-----------
88226012
88226012
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-115VAC-50HZ 12M PANEL*Active-----------
88225034
88225034
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-230VAC-60HZ 12H BASE*Active-----------
88225029
88225029
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-24VAC-60HZ 12M BASE*Active-----------
88225014
88225014
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-230VAC-50HZ 12H BASE*Active-----------
88225013
88225013
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-24VAC-50HZ 12M BASE*Active-----------
88225011
88225011
1+228.059
Increments of 1
Leadtime
2-3 weeks
CrouzetRESET TIMR-230VAC-50HZ 12M BASE*Active-----------
2903171
2903171
1+62.7451
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactPLC-OSC-LPE-24DC/48DC/100*Active-----------
2903173
2903173
1+62.7451
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactPLC-OPT-LPE-24DC/48DC/100*Active-----------
2901481
2901481
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-ON-CC-300S-PTETD-BL-1TActivePlug-In, Factory InstalledOn-DelaySPDT (1 Form C)3 Sec ~ 300 SecMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901484
2901484
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-ON-CC-300MIN-PTETD-BL-1TActivePlug-In, Factory InstalledOn-DelaySPDT (1 Form C)3 Min ~ 300 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901483
2901483
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-ON-CC- 30MIN-PTETD-BL-1TActivePlug-In, Factory InstalledOn-DelaySPDT (1 Form C)0.3 Min ~ 30 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901480
2901480
1+66.1765
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-ON-CC- 10S-PTETD-BL-1TActivePlug-In, Factory InstalledOn-DelaySPDT (1 Form C)0.1 Sec ~ 10 SecMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901477
2901477
1+66.1765
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-ON-300S-PTETD-BL-1TActivePlug-In, Factory InstalledOn-DelaySPDT (1 Form C)3 Sec ~ 300 SecMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901479
2901479
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-ON-300MIN-PTETD-BL-1TActivePlug-In, Factory InstalledOn-DelaySPDT (1 Form C)3 Min ~ 300 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901478
2901478
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-ON- 30MIN-PTETD-BL-1TActivePlug-In, Factory InstalledOn-DelaySPDT (1 Form C)0.3 Min ~ 30 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901486
2901486
1+66.1765
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-OFF-CC-300S-PTETD-BL-1TActivePlug-In, Factory InstalledOff-DelaySPDT (1 Form C)3 Sec ~ 300 SecMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901488
2901488
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-OFF-CC-300MIN-PTETD-BL-1TActivePlug-In, Factory InstalledOff-DelaySPDT (1 Form C)3 Min ~ 300 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901487
2901487
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-OFF-CC- 30MIN-PTETD-BL-1TActivePlug-In, Factory InstalledOff-DelaySPDT (1 Form C)0.3 Min ~ 30 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901485
2901485
1+66.1765
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-OFF-CC- 10S-PTETD-BL-1TActivePlug-In, Factory InstalledOff-DelaySPDT (1 Form C)0.1 Sec ~ 10 SecMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901490
2901490
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-F-300S-PTETD-BL-1TActivePlug-In, Factory InstalledFlasherSPDT (1 Form C)3 Sec ~ 300 SecMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901492
2901492
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-F-300MIN-PTETD-BL-1TActivePlug-In, Factory InstalledFlasherSPDT (1 Form C)3 Min ~ 300 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901491
2901491
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-F- 30MIN-PTETD-BL-1TActivePlug-In, Factory InstalledFlasherSPDT (1 Form C)0.3 Min ~ 30 MinMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage
2901489
2901489
1+64.7059
Increments of 1
Leadtime
2-3 weeks
Phoenix ContactETD-BL-1T-F- 10S-PTETD-BL-1TActivePlug-In, Factory InstalledFlasherSPDT (1 Form C)0.1 Sec ~ 10 SecMechanical Relay6A @ 250VAC24VDCDIN RailPush InScrewdriver SlotInput Voltage