Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Series | Part Status | Relay Type | Function | Circuit | Delay Time | Output Type | Contact Rating @ ... | Voltage - Supply | Mounting Type | Termination Style | Timing Adjustment ... | Timing Initiate Method ... | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
88226014![]() | 88226014 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-230VAC-50HZ 12HR PANE | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
88226013![]() | 88226013 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-24VAC-50HZ 12M PANEL | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
88226012![]() | 88226012 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-115VAC-50HZ 12M PANEL | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
88225034![]() | 88225034 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-230VAC-60HZ 12H BASE | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
88225029![]() | 88225029 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-24VAC-60HZ 12M BASE | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
88225014![]() | 88225014 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-230VAC-50HZ 12H BASE | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
88225013![]() | 88225013 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-24VAC-50HZ 12M BASE | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
88225011![]() | 88225011 |
| Leadtime 2-3 weeks | Crouzet | RESET TIMR-230VAC-50HZ 12M BASE | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
2903171![]() | 2903171 |
| Leadtime 2-3 weeks | Phoenix Contact | PLC-OSC-LPE-24DC/48DC/100 | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
2903173![]() | 2903173 |
| Leadtime 2-3 weeks | Phoenix Contact | PLC-OPT-LPE-24DC/48DC/100 | * | Active | - | - | - | - | - | - | - | - | - | - | - | ||||||
2901481![]() | 2901481 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-ON-CC-300S-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | On-Delay | SPDT (1 Form C) | 3 Sec ~ 300 Sec | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901484![]() | 2901484 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-ON-CC-300MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | On-Delay | SPDT (1 Form C) | 3 Min ~ 300 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901483![]() | 2901483 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-ON-CC- 30MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | On-Delay | SPDT (1 Form C) | 0.3 Min ~ 30 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901480![]() | 2901480 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-ON-CC- 10S-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | On-Delay | SPDT (1 Form C) | 0.1 Sec ~ 10 Sec | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901477![]() | 2901477 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-ON-300S-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | On-Delay | SPDT (1 Form C) | 3 Sec ~ 300 Sec | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901479![]() | 2901479 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-ON-300MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | On-Delay | SPDT (1 Form C) | 3 Min ~ 300 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901478![]() | 2901478 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-ON- 30MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | On-Delay | SPDT (1 Form C) | 0.3 Min ~ 30 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901486![]() | 2901486 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-OFF-CC-300S-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Off-Delay | SPDT (1 Form C) | 3 Sec ~ 300 Sec | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901488![]() | 2901488 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-OFF-CC-300MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Off-Delay | SPDT (1 Form C) | 3 Min ~ 300 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901487![]() | 2901487 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-OFF-CC- 30MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Off-Delay | SPDT (1 Form C) | 0.3 Min ~ 30 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901485![]() | 2901485 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-OFF-CC- 10S-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Off-Delay | SPDT (1 Form C) | 0.1 Sec ~ 10 Sec | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901490![]() | 2901490 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-F-300S-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Flasher | SPDT (1 Form C) | 3 Sec ~ 300 Sec | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901492![]() | 2901492 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-F-300MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Flasher | SPDT (1 Form C) | 3 Min ~ 300 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901491![]() | 2901491 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-F- 30MIN-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Flasher | SPDT (1 Form C) | 0.3 Min ~ 30 Min | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage | ||||||
2901489![]() | 2901489 |
| Leadtime 2-3 weeks | Phoenix Contact | ETD-BL-1T-F- 10S-PT | ETD-BL-1T | Active | Plug-In, Factory Installed | Flasher | SPDT (1 Form C) | 0.1 Sec ~ 10 Sec | Mechanical Relay | 6A @ 250VAC | 24VDC | DIN Rail | Push In | Screwdriver Slot | Input Voltage |