ManufacturerSeriesPart StatusRelay TypeFunctionCircuitDelay TimeOutput TypeContact Rating @ VoltageVoltage - SupplyMounting TypeTermination StyleTiming Adjustment MethodTiming Initiate Method
Supplier Part Number
Manufacturer Part Number
PriceStock
Manufacturer
Description
Series
Part Status
Relay Type
Function
Circuit
Delay Time
Output Type
Contact Rating @ ...
Voltage - Supply
Mounting Type
Termination Style
Timing Adjustment ...
Timing Initiate Method ...
54-P4Y-36S
54-P4Y-36S
10+22.2784
Increments of 10
Leadtime
2-3 weeks
BZB9-2Y48-GZSS TIMR ON DLY, 6M ADJ, 110VAC D*Active-----------
TYCA-6KU-4N8
TYCA-6KU-4N8
2+488.711
Increments of 2
55WT-5SA4-CBRELAY TIME DELAY*Active-----------
F0DQR-E3L-XM5
F0DQR-E3L-XM5
1+228.059
Increments of 1
Leadtime
2-3 weeks
QPC7C-RSK-57ITIMER RESET MEM 12M 110VAC BASE88220ActiveIntegratedProgrammable Multi-Function SPST-NO + SPDT 1 Form A + C 0.3 Sec ~ 12 MinMechanical Relay8A @ 220VAC110VACDIN RailScrew TerminalHand DialInput Voltage
2112D4YF
2112D4YF
2+1856.63
Increments of 2
Leadtime
2-3 weeks
YJ-038M-OMXCOMMERCIAL 2100*Active-----------
PM4HF11R-M-DC12V
PM4HF11R-M-DC12V
1+68.1765
Increments of 1
Leadtime
2-3 weeks
G75B-N5Y-KMANALOG TIMER DIN48 1-10MIN*Active-----------
5-1437446-7
5-1437446-7
2+666.868
Increments of 2
Leadtime
2-3 weeks
Y3-SL-M2RELAY TIME DELAY*Active-----------
H3JA-8A AC100-120 5M
H3JA-8A AC100-120 5M
Leadtime
2-3 weeks
OTE-RBJ9-VHRELAY TIMER SPDT 0.5-5MIN 120VACH3JAObsoleteIntegratedOn-DelaySPDT 1 Form C 0.5 Min ~ 5 MinMechanical Relay7A @ 250VAC100 ~ 120VACSocket8 Pin SocketableHand DialInput Voltage
88867305
88867305
1+112.765
10+106.5
25+100.235
50+93.9706
100+87.7059
Increments of 1
Leadtime
2-3 weeks
TF5-6IVF-SBRRELAY TIME ANALOG 10A 240V 11PINPU2R1ActiveIntegratedProgrammable Multi-Function DPDT 2 Form C 0.1 Sec ~ 100 HrsMechanical Relay10A @ 250VAC24 ~ 240VACSocket11 Pin SocketableHand DialInput Voltage, Trigger Signal
PM4S-A2C10H-DC24V
PM4S-A2C10H-DC24V
1+36.4706
Increments of 1
Leadtime
2-3 weeks
WLG1C-O4-3UJANALOG TIMER 1MIN-10HR*Active-----------
SK-73-0SJ
SK-73-0SJ
2+447.039
Increments of 2
101-W8NC-Y0RELAY TIME DELAY*Active-----------
S1DX-S4C5S-DC24V
S1DX-S4C5S-DC24V
1+53.2059
Increments of 1
Leadtime
2-3 weeks
ERY-ZW-ZPDPOWER ONE SHOT 4 FORM C*Active-----------
2-1472995-9
2-1472995-9
2+652.564
Increments of 2
Leadtime
2-3 weeks
UBX-YCI5-RNQRELAY TIME DELAY*Active-----------
3-1472969-1
3-1472969-1
10+280.178
Increments of 10
99YI1S-3KM-M8PRELAY TIME DELAY*Active-----------
H3DS-FL AC24-230 DC24-48
H3DS-FL AC24-230 DC24-48
1+96.8137
10+91.7206
25+86.6251
50+81.5294
100+76.4338
Increments of 1
Leadtime
2-3 weeks
FM6D-J1-R1LRELAY TIME DELAY 1MODE DIN MNTH3DS-FActiveIntegratedRepeat Cycle, Twin TimerSPDT 1 Form C 0.1 Sec ~ 12 HrsMechanical Relay5A @ 250VAC24 ~ 230VAC, 24 ~ 48VDCDIN RailScrew TerminalScrewdriver SlotInput Voltage, Trigger Signal
YBLP-P7-GIW
YBLP-P7-GIW
1+319.49
Increments of 1
Leadtime
2-3 weeks
R1-3LUT-LH2TIMER DGTL 4DIGIT DISPLAY 8PINH5CNActiveIntegratedOn-DelaySPDT 1 Form C 1 Min ~ 99 Hrs 59 MinMechanical Relay3A @ 250VAC12 ~ 48VDCSocket8 Pin SocketableUp Down Digit KeysInput Voltage
CRB-48-70060
CRB-48-70060
6+327.706
Increments of 6
1212-8C-RT4RELAY TIME DELAY .6-60SEC 120VACCRActiveIntegratedRepeat Cycle, Twin TimerDPDT 2 Form C 0.6 Sec ~ 60 SecMechanical Relay10A @ 277VAC120VACSocket8 Pin SocketableHand DialInput Voltage
3-1472981-5
3-1472981-5
2+549.005
Increments of 2
22RNE2-LIYM-MBRELAY TIME DELAY*Active-----------
9LH-6S-CV
9LH-6S-CV
1+465.167
Increments of 1
77BJKH-AXW-AL2SST 0.2STO12H WITH WATERPROOFH3AMActiveIntegratedOn-DelayDPDT 2 Form C 0.2 Sec ~ 12 HrsMechanical Relay5A @ 250VAC100 ~ 240VACPanel MountScrew TerminalHand DialInput Voltage
SHSP30S24A
SHSP30S24A
5+35.8235
Increments of 5
Leadtime
2-3 weeks
HZ-UN-UEPTIMER INTRVL 30S 24VAC DIN MOUNTSHSActiveIntegratedInterval-0.1 Sec ~ 30 SecSolid State Relay-24VACDIN RailQuick Connect - 0.250 6.3mm PotentiometerInput Voltage
3-1423154-4
3-1423154-4
2+2144.41
Increments of 2
Leadtime
2-3 weeks
COA-GPW-AACOMMERCIAL 2100*Active-----------
9-1472973-3
9-1472973-3
2+410.529
Increments of 2
22S-MD6-PGGRELAY TIME DELAY*Active-----------
H3JA-8C DC24 1S
H3JA-8C DC24 1S
Leadtime
2-3 weeks
EGXKD-7PTD-OZQRELAY TIMER DPDT 0.1-1SEC 24VDCH3JAObsoleteIntegratedOn-DelayDPDT 2 Form C 0.1 Sec ~ 1 SecMechanical Relay5A @ 250VAC24VDCSocket8 Pin SocketableHand DialInput Voltage
PM4HF8-M-AC240VW
PM4HF8-M-AC240VW
1+77.1177
Increments of 1
Leadtime
2-3 weeks
KJAC-JQ-8U4ANALOG TIMER DIN48 IP65 1-10 MIN*Active-----------
G2-HH-3X
G2-HH-3X
2+697.765
Increments of 2
Leadtime
2-3 weeks
WMBZ7-VM3B-3LRELAY TIME DELAY*Active-----------
H5CN-XBN DC12-48
H5CN-XBN DC12-48
1+319.49
Increments of 1
99DLO4-KK-66TIMER DGTL 4DIGIT DISPLAY 8PINH5CNActiveIntegratedOn-DelaySPDT 1 Form C 0.001 Sec ~ 99.99 SecMechanical Relay3A @ 250VAC12 ~ 48VDCSocket8 Pin SocketableUp Down Digit KeysInput Voltage