ManufacturerSeriesPart StatusTypeVoltage - SupplySensitivityFeaturesCable LengthOutput TypeContact FormContact Rating @ VoltageMounting TypeTermination StyleOperating Temperature
Supplier Part Number
Manufacturer Part Number
PriceStock
Manufacturer
Description
Series
Part Status
Type
Voltage - Supply
Sensitivity
Features
Cable Length
Output Type
Contact Form
Contact Rating @ ...
Mounting Type
Termination Style
Operating Temperature ...
A8-54Y-2F
A8-54Y-2F
1+218.873
Increments of 1
Leadtime
2-3 weeks
C6WY9-C0F-H3CONTROL LIQ LEVEL 120VAC CHASSISLCSActiveHigh Low Level120VAC0 ~ 100kOhmAdjustable Sensitivity, Auxiliary Contactor-RelaySPDT 1 Form C 10A @ 120VACChassis MountScrew Terminal0°C ~ 60°C
L1RJ1-MHV6-94
L1RJ1-MHV6-94
1+342.725
Increments of 1
66JDP-9LK2-85CNTRL LIQ LEV 110VAC SOCKETABLE61FActiveHigh Low Level110VAC0 ~ 4kOhmAlarm High Low - Contact, Level Indication1km Not Included Relay 2 SPDT 2 Form C 5A @ 200VACSocketablePlug In, 14 Pin Octal -10°C ~ 55°C
31QZR-M0V-AB1
31QZR-M0V-AB1
44QD1-T9MF-NS1CONTROL LIQ LEV 230VAC DIN RAILENObsoleteConstant Level230VAC5kOhm ~ 100kOhmAdjustable Sensitivity-RelaySPDT 1 Form C 8ADIN RailScrew Terminal-20°C ~ 60°C
1QCT-VNSI-QO3
1QCT-VNSI-QO3
1+180.078
Increments of 1
Leadtime
2 3 weeks
AVVQ-QN4J-11CNTRL LIQ LEV 120VAC SOCKETABLE61FActiveHigh Low Level120VAC0 ~ 4kOhm SocketablePlug In, 8 Pin Octal 10°C ~ 55°C
61F-GNL AC110 220 4KM
61F-GNL AC110 220 4KM
1+290.441
Increments of 1
Leadtime
2-3 weeks
TL-2DE-CJQCNTRL LIQ LEV 110 220VAC DINRAIL61FActiveHigh Low Level110 220VAC0 ~ 0.7kOhm-4km Not Included RelaySPDT 2 Form C 3A @ 200VACDIN RailScrew Terminal-10°C ~ 55°C
BUA3X-BU-5H
BUA3X-BU-5H
1+377.578
Increments of 1
Leadtime
2-3 weeks
XBSHX-H3Q-X2FCNTRL LIQ LEV 110 220VAC DINRAIL61FActiveHigh Low Level110 220VAC10kOhm ~ 40kOhmAlarm High - Contact50m Not Included Relay 2 SPDT 1 Form C , SPDT 2 Form C 3A @ 200VACDIN RailScrew Terminal-10°C ~ 55°C
61F-GP-NT AC240
61F-GP-NT AC240
1+313.676
Increments of 1
22XZ5S-R5-FXCNTRL LIQ LEV 240VAC SOCKETABLE61FActiveHigh Low Level240VAC0 ~ 4kOhm-600m Not Included RelaySPDT 2 Form C 3A @ 250VACSocketablePlug In, 8 Pin Octal -10°C ~ 55°C
51L-UI-CPL
51L-UI-CPL
Leadtime
2 3 weeks
0A-BNAR-79CONTROL LIQ LEV 230VAC DIN RAILENObsoleteConstant Level230VAC5kOhm ~ 100kOhmAdjustable Sensitivity RelaySPDT 1 Form C 8ADIN RailScrew Terminal 20°C ~ 60°C
TI74-92X-6YM
TI74-92X-6YM
1+453.088
Increments of 1
Leadtime
2-3 weeks
C4OS-HEY-MO1CNTRL LIQ LEV 120 240VAC DINRAIL61FActiveHigh Low Level120 240VAC0 ~ 1.8kOhmAlarm High - Contact1km Not Included Relay 3 SPDT 2 Form C 3A @ 200VACDIN RailScrew Terminal-10°C ~ 55°C
STCYC 4D B2M
STCYC 4D B2M
1+473.078
Increments of 1
Leadtime
2 3 weeks
JVG-UP8-U9CONTROL LIQ LEVEL 120VAC CHASSISLHSActiveHigh Low Level120VAC0 ~ 3MOhmAdjustable Sensitivity, NEMA 4 Rated Enclosure Included RelaySPDT 1 Form C 10A @ 120VACChassis MountScrew Terminal0°C ~ 60°C
61F-G3NL AC120 240 2KM
61F-G3NL AC120 240 2KM
1+435.667
Increments of 1
3939Q-JL0-3DGCNTRL LIQ LEV 120 240VAC DINRAIL61FActiveHigh Low Level120 240VAC0 ~ 1.8kOhmAlarm High - Contact2km Not Included Relay 3 SPDT 2 Form C 3A @ 200VACDIN RailScrew Terminal-10°C ~ 55°C
61F-GP-N AC110
61F-GP-N AC110
1+273.02
Increments of 1
961961J-V2F-SLCNTRL LIQ LEV 110VAC SOCKETABLE61FActiveHigh Low Level110VAC0 ~ 4kOhmLevel Indication1km Not Included RelaySPDT 2 Form C 3A @ 250VACSocketablePlug In, 11 Pin Octal -10°C ~ 55°C
DBJ3X-KV-QO2
DBJ3X-KV-QO2
1+435.667
Increments of 1
Leadtime
2-3 weeks
G4-D6F1-Z9CNTRL LIQ LEV 120 240VAC DINRAIL61FActiveHigh Low Level120 240VAC0 ~ 1.8kOhmAlarm High - Contact2km Not Included Relay 3 SPDT 2 Form C 3A @ 200VACDIN RailScrew Terminal-10°C ~ 55°C
6R8-DG-RG
6R8-DG-RG
1+456.569
Increments of 1
Leadtime
2-3 weeks
HYJQ6-AMBD-VTCONTROL LIQ LEVEL 240VAC CHASSISDLCActiveHigh Low Level240VAC0 ~ 100kOhmLockout Feature, NEMA 4 Rated Enclosure Included-Relay 2 SPST 1 Form A , SPDT 1 Form C 10A @ 120VACChassis MountQuick Connect - 0.250 6.3mm 0°C ~ 60°C
70BG-U58-6M
70BG-U58-6M
1+331.069
Increments of 1
Leadtime
2-3 weeks
OM-J8L0-DBCCONTROL LIQ LEVEL 120VAC CHASSISLHSActiveHigh Low Level120VAC0 ~ 3MOhmAdjustable Sensitivity, NEMA 3 Rated Enclosure Included-RelaySPDT 1 Form C 10A @ 120VACChassis MountScrew Terminal0°C ~ 60°C
L1RJ1-MHV6-94
L1RJ1-MHV6-94
1+342.725
Increments of 1
Leadtime
2-3 weeks
GC4P-FTL-MXCNTRL LIQ LEV 110VAC SOCKETABLE61FActiveHigh Low Level110VAC0 ~ 4kOhmAlarm High Low - Contact, Level Indication1km Not Included Relay 2 SPDT 2 Form C 5A @ 200VACSocketablePlug In, 14 Pin Octal -10°C ~ 55°C
JD3-ECBA-IY
JD3-ECBA-IY
1+68.1177
Increments of 1
Leadtime
2-3 weeks
PS3F-7MO-8FCONTROL LIQ LEV 24VAC SOCKETABLENRActiveHigh Low Level24VAC4.7kOhm ~ 100kOhmAdjustable Sensitivity-RelaySPDT 1 Form C 10A @ 250VACSocketablePlug In, 11 Pin Octal -10°C ~ 60°C
16-XGQ5-LZ
16-XGQ5-LZ
1+214.931
Increments of 1
22T-BT3P-UKPCNTRL LIQ LEV 100VAC SOCKETABLE61FActiveHigh Low Level100VAC0 ~ 4kOhm-1km Not Included RelaySPDT 2 Form C 3A @ 250VACSocketablePlug In, 8 Pin Octal -10°C ~ 55°C
YDZ-MFV-80U
YDZ-MFV-80U
33L-A9WK-8CCONTROL LIQUID LEV 24VAC CHASSISLCObsoleteHigh Low Level24VAC0 ~ 100kOhmAdjustable Sensitivity RelayDPDT 2 Form C 10A @ 120VACChassis MountScrew Terminal0°C ~ 60°C
LCS-30
LCS-30
1+148.588
10+139.847
25+135.477
50+126.737
Increments of 1
Leadtime
2-3 weeks
ZSV-V54C-O58CONTROL LIQUID LEV 24VAC CHASSISLCSActiveHigh Low Level24VAC0 ~ 100kOhmAdjustable Sensitivity-RelaySPDT 1 Form C 10A @ 120VACChassis MountScrew Terminal0°C ~ 60°C
ZJ2-T6X-BBF
ZJ2-T6X-BBF
1+377.578
Increments of 1
66A1B-VTHO-Z0CNTRL LIQ LEV 110 220VAC DINRAIL61FActiveHigh Low Level110 220VAC0 ~ 0.7kOhmAlarm High Contact4km Not Included Relay 2 SPDT 1 Form C , SPDT 2 Form C 3A @ 200VACDIN RailScrew Terminal 10°C ~ 55°C
UOUC-5K-AP
UOUC-5K-AP
1+267.206
Increments of 1
77HL-SHJ-EJ8CNTRL LIQ LEV 110VAC SOCKETABLE61FActiveHigh Low Level110VAC0 ~ 4kOhm-600m Not Included RelaySPDT 2 Form C 3A @ 250VACSocketablePlug In, 8 Pin Octal -10°C ~ 55°C
RFD5 RG8 TQP
RFD5 RG8 TQP
1+537.598
Increments of 1
Leadtime
2 3 weeks
IOSHH-41J-W3CONTROL LIQ LEVEL 120VAC CHASSISLHSActiveHigh Low Level120VAC0 ~ 3MOhmAdjustable Sensitivity, Auxiliary Contactor, NEMA 4 Rated Enclosure Included RelaySPDT 1 Form C 10A @ 120VACChassis MountScrew Terminal0°C ~ 60°C
SM20
SM20
5+91.1647
Increments of 5
Leadtime
2-3 weeks
Y6XZA-M3-6ICONTROL LIQ LEVEL 240 415VAC DIN-ActiveHigh Low Level240, 415VAC---Relay 2 SPDT 1 Form C 20A @ 250VACDIN RailScrew Terminal-
CO5TE-QDRQ-JPV
CO5TE-QDRQ-JPV
1+505.373
Increments of 1
Leadtime
2-3 weeks
MIYDV-RAE-EBCNTRL LIQ LEV 110 220VAC DINRAIL61FActiveHigh Low Level110 220VAC0 ~ 4kOhmIdling Prevention, Level Indication1km Not Included Relay 6 SPDT 2 Form C , SPDT 3 Form C 3A @ 200VACDIN RailScrew Terminal-10°C ~ 55°C