ManufacturerSeriesPart StatusFilter TypeConfigurationVoltage - Rated DCVoltage - Rated ACVoltage - Rated AC (Phase to Ground/Neutral)Voltage - Rated AC (Phase to Phase)CurrentFrequency - OperatingApplicationsApprovalsOperating TemperatureMounting TypeTermination StyleInductance
Supplier Part Number
Manufacturer Part Number
PriceStock
Manufacturer
Description
Series
Part Status
Filter Type
Configuration
Voltage - Rated DC
Voltage - Rated AC
Voltage - Rated AC ...
Voltage - Rated AC ...
Current
Frequency - Operating ...
Applications
Approvals
Operating Temperature ...
Mounting Type
Termination Style
Inductance
F3480T009
F3480T009
1+146.127
Increments of 1
Leadtime
2-3 weeks
Curtis IndustriesLINE FILTER 480VAC 9A CHASS MNTF3480ActiveThree Phase (Delta)Two Stage-480V--9A50/60HzGeneral PurposeCE, UR-Chassis MountTerminal Block-
F3600T600
F3600T600
1+2834.17
Increments of 1
Leadtime
2-3 weeks
Curtis IndustriesLINE FILTER 600VAC 600A CHASSF3600ActiveThree Phase (Wye)Two Stage-600V--600A50/60HzGeneral PurposeUR-Chassis MountTerminal Block-
F3600T300
F3600T300
1+1794.15
Increments of 1
Leadtime
2-3 weeks
Curtis IndustriesLINE FILTER 600VAC 300A CHASSF3600ActiveThree Phase (Wye)Two Stage-600V--300A50/60HzGeneral PurposeUR-Chassis MountTerminal Block-
F3600T180
F3600T180
1+1048.78
Increments of 1
Leadtime
2-3 weeks
Curtis IndustriesLINE FILTER 600VAC 180A CHASSF3600ActiveThree Phase (Wye)Two Stage-600V--180A50/60HzGeneral PurposeUR-Chassis MountTerminal Block-
F3600T025
F3600T025
1+268.157
Increments of 1
Leadtime
2-3 weeks
Curtis IndustriesLINE FILTER 600VAC 25A CHASS MNTF3600ActiveThree Phase (Wye)Two Stage-600V--25A50/60HzGeneral PurposeUR-Chassis MountTerminal Block-
F3600T008
F3600T008
1+162.353
Increments of 1
Leadtime
2-3 weeks
Curtis IndustriesLINE FILTER 600VAC 8A CHASS MNTF3600ActiveThree Phase (Wye)Two Stage-600V--8A50/60HzGeneral PurposeUR-Chassis MountTerminal Block-
FN3268-75-34
FN3268-75-34
1+475.686
10+459.828
Increments of 1
Leadtime
2-3 weeks
Schaffner EMC Inc.LINE FILTER 75A CHASSIS MOUNTFN 3268ActiveThree Phase (Delta)Single Stage--300V520V75ADC ~ 60HzGeneral PurposeCSA, ENEC, UR-25°C ~ 100°CChassis MountTerminal Block-
3-1609037-3
3-1609037-3
1+71.8824
10+69.5588
25+67.2404
50+64.9216
100+62.6029
Increments of 1
Leadtime
2-3 weeks
TE Connectivity Corcom FiltersLINE FILTER 250VAC 30A CHASS MNTHZActiveSingle PhaseSingle Stage-250V--30A50/60HzGeneral PurposeCSA, UR, VDE-10°C ~ 40°CChassis MountThreaded Post (8-32)900µH
3-1609037-2
3-1609037-2
1+48.3235
10+46.7667
25+45.2075
50+43.6484
100+42.0896
Increments of 1
Leadtime
2-3 weeks
TE Connectivity Corcom FiltersLINE FILTER 250VAC 20A CHASS MNTHZActiveSingle PhaseSingle Stage-250V--20A50/60HzGeneral PurposeCSA, UR, VDE-10°C ~ 40°CChassis MountQuick Connect4.55mH
3-1609037-1
3-1609037-1
1+47.8726
10+46.3294
25+44.7851
50+43.2408
100+41.6965
Increments of 1
Leadtime
2-3 weeks
TE Connectivity Corcom FiltersLINE FILTER 250VAC 15A CHASS MNTHZActiveSingle PhaseSingle Stage-250V--15A50/60HzGeneral PurposeCSA, UR, VDE-10°C ~ 40°CChassis MountQuick Connect5.04mH
3-1609037-0
3-1609037-0
1+36.6275
10+35.4873
25+34.3427
50+33.1978
100+32.0531
Increments of 1
Leadtime
2-3 weeks
TE Connectivity Corcom FiltersLINE FILTER 250VAC 10A CHASS MNTHZActiveSingle PhaseSingle Stage-250V--10A50/60HzGeneral PurposeCSA, UR, VDE-10°C ~ 40°CChassis MountQuick Connect4.97mH
2-1609037-9
2-1609037-9
1+25.1765
10+24.4157
25+23.6525
50+22.8898
100+22.1268
Increments of 1
Leadtime
2-3 weeks
TE Connectivity Corcom FiltersLINE FILTER 250VAC 6A CHASS MNTHZActiveSingle PhaseSingle Stage-250V--6A50/60HzGeneral PurposeCSA, UR, VDE-10°C ~ 40°CChassis MountQuick Connect5.1mH
2-1609037-8
2-1609037-8
1+26.3824
10+25.5578
25+24.7337
50+23.9094
100+23.0849
Increments of 1
Leadtime
2-3 weeks
TE Connectivity Corcom FiltersLINE FILTER 250VAC 4A CHASS MNTHZActiveSingle PhaseSingle Stage-250V--4A50/60HzGeneral PurposeCSA, UR, VDE-10°C ~ 40°CChassis MountQuick Connect7mH
FMW-95-0001
FMW-95-0001
5+83.2255
Increments of 5
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 250/440VAC 6A CHASFMW4-81(95)ActiveThree Phase (Wye)Two Stage-250V, 440V--6A50/60HzGeneral PurposeENEC, VDE-25°C ~ 100°CChassis MountQuick ConnectL1 - 500µH, L2 - 4µH
FMW-81-0001
FMW-81-0001
5+73.2373
Increments of 5
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 250/440VAC 4A CHASFMW4-81(95)ActiveThree Phase (Wye)Two Stage-250V, 440V--4A50/60HzGeneral PurposeENEC, VDE-25°C ~ 100°CChassis MountQuick ConnectL1 - 400µH, L2 - 4µH
FMW-65-0004
FMW-65-0004
10+27.3735
Increments of 10
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 250/440VAC 10A CHASSFMW4-65ActiveThree Phase (Wye)Single Stage-250V, 440V--10A50/60HzGeneral PurposeENEC, VDE-25°C ~ 100°CChassis MountQuick Connect400µH
FMW-65-0003
FMW-65-0003
10+27.3735
Increments of 10
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 250/440VAC 10A CHASSFMW4-65ActiveThree Phase (Wye)Single Stage-250V, 440V--10A50/60HzGeneral PurposeENEC, VDE-25°C ~ 100°CChassis MountQuick Connect400µH
FMW-65-0001
FMW-65-0001
10+25.5784
Increments of 10
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 250/440VAC 3A CHASFMW4-65ActiveThree Phase (Wye)Single Stage-250V, 440V--3A50/60HzGeneral PurposeENEC, VDE-25°C ~ 100°CChassis MountQuick Connect1mH
FMBD-B92F-K012
FMBD-B92F-K012
1+1189.02
Increments of 1
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 300/520VAC 200A CHASFMBD NEOActiveThree Phase (Wye)Two Stage-300V, 520V--200A50/60HzGeneral PurposecURus, ENEC, VDE-25°C ~ 100°CChassis MountTerminal BlockL1 - 300µH, L2 - 9µH
FMBD-B92F-J612
FMBD-B92F-J612
1+955.902
Increments of 1
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 300/520VAC 160A CHASFMBD NEOActiveThree Phase (Wye)Two Stage-300V, 520V--160A50/60HzGeneral PurposecURus, ENEC, VDE-25°C ~ 100°CChassis MountTerminal BlockL1 - 400µH, L2 - 9µH
FMBD-B92E-J212
FMBD-B92E-J212
1+776.804
Increments of 1
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 300/520VAC 120A CHASFMBD NEOActiveThree Phase (Wye)Two Stage-300V, 520V--120A50/60HzGeneral PurposecURus, ENEC, VDE-25°C ~ 100°CChassis MountTerminal BlockL1 - 600µH, L2 - 9µH
FMBD-B92D-8012
FMBD-B92D-8012
1+627.52
Increments of 1
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 300/520VAC 80A CHASSFMBD NEOActiveThree Phase (Wye)Two Stage-300V, 520V--80A50/60HzGeneral PurposecURus, ENEC, VDE-25°C ~ 100°CChassis MountTerminal BlockL1 - 600µH, L2 - 9µH
FMBD-B92C-6412
FMBD-B92C-6412
1+369.892
Increments of 1
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 300/520VAC 64A CHASSFMBD NEOActiveThree Phase (Wye)Two Stage-300V, 520V--64A50/60HzGeneral PurposecURus, ENEC, VDE-25°C ~ 100°CChassis MountTerminal BlockL1 - 700µH, L2 - 7.5mH
FMBD-B92B-3612
FMBD-B92B-3612
2+263.064
Increments of 2
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 300/520VAC 36A CHASSFMBD NEOActiveThree Phase (Wye)Two Stage-300V, 520V--36A50/60HzGeneral PurposecURus, ENEC, VDE-25°C ~ 100°CChassis MountTerminal BlockL1 - 1mH, L2 - 12µH
FMBD-B92B-2512
FMBD-B92B-2512
2+245.471
Increments of 2
Leadtime
2-3 weeks
Schurter Inc.LINE FILTER 300/520VAC 25A CHASSFMBD NEOActiveThree Phase (Wye)Two Stage-300V, 520V--25A50/60HzGeneral PurposecURus, ENEC, VDE-25°C ~ 100°CChassis MountTerminal BlockL1 - 1.6mH, L2 - 12µH