Supplier Part Number | Manufacturer Part Number | Price | Stock | Manufacturer | Description | Packaging | Series | Part Status | Terminal Type | Stud/Tab Size | Terminal Style | Tab Thickness | Length - Overall | Width - Outer Edges | Mounting Type | Termination | Wire Gauge | Insulation | Features | Color | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LCAF1/0-14F-X![]() | LCAF1/0-14F-X |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 1/0 AWG #1/4 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 1/4 Stud | Single Stud Hole | 0.130" (3.30mm) | - | 0.850" (21.59mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 1/0 AWG | Non-Insulated | - | Black | ||||||||||||||
LCAF1/0-12H-X![]() | LCAF1/0-12H-X |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 1/0 AWG #1/2 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 1/2 Stud | Single Stud Hole | 0.130" (3.30mm) | - | 0.850" (21.59mm) | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 1/0 AWG | Non-Insulated | - | Black | ||||||||||||||
LCAF1/0-12F-X![]() | LCAF1/0-12F-X |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 1/0 AWG #1/2 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 1/2 Stud | Single Stud Hole | 0.130" (3.30mm) | - | 0.850" (21.59mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 1/0 AWG | Non-Insulated | - | Black | ||||||||||||||
LCA8-56-L![]() | LCA8-56-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #5/16 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/16 Stud | Single Stud Hole | 0.050" (1.27mm) | 1.460" (37.10mm) | 0.560" (14.22mm) | Free Hanging (In-Line) | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-56H-L![]() | LCA8-56H-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #5/16 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/16 Stud | Single Stud Hole | 0.050" (1.27mm) | - | 0.560" (14.22mm) | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-56F-L![]() | LCA8-56F-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #5/16 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/16 Stud | Single Stud Hole | 0.050" (1.27mm) | - | 0.560" (14.22mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-38-M![]() | LCA8-38-M |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #3/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 3/8 Stud | Single Stud Hole | 0.050" (1.27mm) | 1.560" (39.62mm) | 0.600" (15.24mm) | Free Hanging (In-Line) | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-38H-L![]() | LCA8-38H-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #3/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 3/8 Stud | Single Stud Hole | 0.050" (1.27mm) | - | 0.600" (15.24mm) | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-38F-L![]() | LCA8-38F-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #3/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 3/8 Stud | Single Stud Hole | 0.050" (1.27mm) | - | 0.600" (15.24mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-14-M![]() | LCA8-14-M |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #1/4 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 1/4 Stud | Single Stud Hole | 0.070" (1.78mm) | 1.340" (34.04mm) | 0.480" (12.19mm) | Free Hanging (In-Line) | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-14H-L![]() | LCA8-14H-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #1/4 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 1/4 Stud | Single Stud Hole | 0.070" (1.78mm) | - | 0.480" (12.19mm) | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-14F-L![]() | LCA8-14F-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #1/4 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 1/4 Stud | Single Stud Hole | 0.070" (1.78mm) | - | 0.480" (12.19mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-10H-L![]() | LCA8-10H-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #10 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 10 Stud | Single Stud Hole | 0.080" (2.03mm) | - | 0.410" (10.41mm) | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-10F-L![]() | LCA8-10F-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG #10 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 10 Stud | Single Stud Hole | 0.080" (2.03mm) | - | 0.410" (10.41mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA8-00-L![]() | LCA8-00-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 8 AWG | Bulk | Pan-Lug® | Active | Rectangular Tongue | - | No Stud Hole | 0.050" (1.27mm) | 1.560" (39.62mm) | 0.600" (15.24mm) | Free Hanging (In-Line) | Crimp, Barrel | 8 AWG | Non-Insulated | - | Red | ||||||||||||||
LCA750-58H-6![]() | LCA750-58H-6 |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 750 MCM #5/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/8 Stud | Single Stud Hole | - | - | - | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 750 MCM (kcmil) | Non-Insulated | - | Black | ||||||||||||||
LCA750-58-6![]() | LCA750-58-6 |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 750 MCM #5/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/8 Stud | Single Stud Hole | 0.260" (6.60mm) | 4.580" (116.33mm) | 1.890" (48.01mm) | Free Hanging (In-Line) | Crimp, Barrel | 750 MCM (kcmil) | Non-Insulated | - | Black | ||||||||||||||
LCA750-12UP-6![]() | LCA750-12UP-6 | Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 750 MCM #1/2 | Bulk | Pan-Lug® | Obsolete | Rectangular Tongue | 1/2 Stud | Single Stud Hole | - | - | - | Free Hanging (In-Line) | Crimp, Barrel | 750 MCM (kcmil) | Non-Insulated | - | Black | |||||||||||||||
LCA6-56-L![]() | LCA6-56-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 6 AWG #5/16 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/16 Stud | Single Stud Hole | 0.070" (1.78mm) | 1.730" (43.94mm) | 0.560" (14.22mm) | Free Hanging (In-Line) | Crimp, Barrel | 6 AWG | Non-Insulated | - | Blue | ||||||||||||||
LCA6-56H-L![]() | LCA6-56H-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 6 AWG #5/16 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/16 Stud | Single Stud Hole | 0.070" (1.78mm) | - | 0.560" (14.22mm) | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 6 AWG | Non-Insulated | - | Blue | ||||||||||||||
LCA6-56F-L![]() | LCA6-56F-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 6 AWG #5/16 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 5/16 Stud | Single Stud Hole | 0.070" (1.78mm) | - | 0.560" (14.22mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 6 AWG | Non-Insulated | - | Blue | ||||||||||||||
LCA6-38-M![]() | LCA6-38-M |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 6 AWG #3/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 3/8 Stud | Single Stud Hole | 0.060" (1.52mm) | 1.830" (46.48mm) | 0.620" (15.75mm) | Free Hanging (In-Line) | Crimp, Barrel | 6 AWG | Non-Insulated | - | Blue | ||||||||||||||
LCA6-38-L | LCA6-38-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 6 AWG #3/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 3/8 Stud | Single Stud Hole | 0.060" (1.52mm) | 1.830" (46.48mm) | 0.620" (15.75mm) | Free Hanging (In-Line) | Crimp, Barrel | 6 AWG | Non-Insulated | - | Blue | ||||||||||||||
LCA6-38H-L![]() | LCA6-38H-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 6 AWG #3/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 3/8 Stud | Single Stud Hole | 0.060" (1.52mm) | - | 0.620" (15.75mm) | Free Hanging (In-Line), 45° Angle | Crimp, Barrel | 6 AWG | Non-Insulated | - | Blue | ||||||||||||||
LCA6-38F-L![]() | LCA6-38F-L |
| Leadtime 2-3 weeks | Panduit Corp | CONN TERM RECT TONG 6 AWG #3/8 | Bulk | Pan-Lug® | Active | Rectangular Tongue | 3/8 Stud | Single Stud Hole | 0.060" (1.52mm) | - | 0.620" (15.75mm) | Free Hanging (In-Line), Right Angle | Crimp, Barrel | 6 AWG | Non-Insulated | - | Blue |